Installation and Operating Instructions
Air Curtain
Model AC6
08/17132/ 0
IMPORTANT
These instructions should be read and carefully retained by the user.
The installation of this appliance should be carried out by a competent electrician and be in
accordance with the current IEE wiring regulations. Tools required are an electrical screwdriver with a
3mm wide blade, a No 2 posidriver, a 7mm AF open ended or box spanner, an 8mm open ended
spanner.
Special instructions on Fitting the heater to a wall or ceiling:-
Solid brick or concrete walls must be drilled and plugged with Rawlplug No 10 size FIBRE inserts.
The plug must be located in the solid part of the wall, not just in the plaster layer.
For panelled internal walls or ceilings, it is best to locate the studding, position the heater fixing
bracket accordingly and use No 10 size wood screws. If it is not possible to locate the studding, use
type M5 Rawlplug INTERSETS, making the 1Omm holes with a drill rather than a bradawl or a
screwdriver.
DO NOT COVER OR OBSTRUCT
the air inlet or outlet grille.
Fixing Positions
Ceiling
mounting
Wall
mounting
Heaters may be mounted end to end for wide doorways
Tel:
+44
(0)191 490 1547
Fax:
+44
(0)191 477 5371
Email:
Website:
www.heattracing.co.uk
www.thorneanderrick.co.uk