Dimplex SKG20BL Installation And Operating Instructions Download Page 3

Operation

The controls are located behind the 

doors (see Fig. 2).

Connect the fire to your electricity supply.

Fig. 2

Note: 

When either the remote control or the manual controls

are used, the neon’s will come on for 3 seconds indicating
the relevant setting (see fig. 3).

neon’s  for indicating
the operation level

Fig. 3

1.

Slide open the battery cover on the back of the remote
control

2.

Install two AAA batteries into the remote control (see
Fig. 4)

3.

Replace the battery cover.

Battery information

Fig. 4

Batteries

Discard leaky batteries

Dispose of batteries in the proper manner according to
Provincial and local regulations. Any battery may leak electrolyte
if mixed with a different battery type, if inserted incorrectly, if all
the batteries are not replaced at the same time, if disposed of
in a fire or if an attempt is made to charge a battery not intended
to be recharged.

Fig. 5

Manual or Remote Operation

Thermal Safety Cut-out

A thermal safety cut-out is incorporated in the heater to
prevent damage due to overheating.

This can happen if the heat outlet was restricted in any way.
The heater will switch on once the obstruction has been
removed and the heater has cooled.  If the cut-out continues
to operate intermittently, the heater should be switched off
and a service agent contacted.

Maintenance

WARNING: ALWAYS DISCONNECT FROM THE POWER
SUPPLY

 

BEFORE ATTEMPTING ANY MAINTENANCE.

Remote Control

Warning: it takes time for
the receiver to respond
to the transmitter. Do not
press the buttons more
than once within two
seconds for correct
operation.

To turn off any of the
settings

Press the           button once

Setting

Operation

Indication

Flame effect

Press the ‘I’ button once

Bottom Neon

Flame effect & 1kW heat

Press the ‘I’ button again

Bottom &
Middle Neon

Flame effect & 2kW heat

Press the ‘I’ button again

All 3 Neon’s

=  Standby

=  On

OFF

ON

Note : The ON/OFF Switch must first be turned on to
operate either the manual or the remote controls.

Thermostat (T) - see Fig. 2

In order to maintain a certain room temperature, set
thecontroller to ‘max.’. Operate the appliance at full power
untilthe required room temperature is reached. Set back
thethermostatic controller until the appliance switches off
withan audible “click”. This temperature will be kept
almostconstant by the thermostatic control switching on
and offautomatically.Please note that the appliance can
only beswitched on when the thermostat setting is higher
then theroom temperature.

T

Controls