background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

SELBORNE 5 S

SELBORNE 5 S

SELBORNE 5 S

SELBORNE 5 SE

E

E

E

    

SMOKE EXEMPT WOODBURNING STOVE

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

INSTALLATION & USER INSTRUCTIONS 

(TO BE LEFT WITH THE CUSTOMER) 

 

UK & Ireland

 

 
 
 
 
 
 
 

GB  IE 

 

 

 
 

General Safety Notes 

Page 2 

Operating Instructions 

Page 8

Chimney & Flue 

Page 3 

Woodburning 

Page 8

Flue Draught 

Page 5 

Maintenance 

Page 10

Dimensions & Clearances 

Page 6 

Guarantee 

Page 12

Installing the Stove 

Page 6 

 

 
 
 

 

 

Properly  installed,  operated  and  maintained,  this  appliance  will  not  emit  fumes  into  the  dwelling. 

However  occasional  fumes  from  de-ashing  and  re-fuelling  may  occur.  Persistent  fume  emissions  is 

potentially dangerous and must not be tolerated. If fume emission does persist, open doors and windows 

to ventilate the room. Let the fire burn out or eject and safely dispose of fuel from the appliance. Once the 

fire is cold, check the flue and chimney for blockages and clean if required. Do not attempt to relight the 

fire  until  the  cause  of  the  fume  emission  has  been  identified  and  corrected.  Seek  expert  advice  if 

necessary.  

 

Do not fit an extractor fan in the same room as the appliance. 

 

An adequate air supply for combustion and ventilation is required. As this stove does not exceed 5.0 kW 

nominal  heat  output  (Refer  to  Building  Regulations  Document  J)  a  purpose  provided  air  vent  is  not 

normally required. However, in certain circumstances a purpose provided air vent may be necessary – for 

example, small or tightly sealed rooms. Air openings provided for this purpose must not be restricted. 

 

It is important that flue ways are cleaned frequently and the chimney swept regularly. Also the stove must 

be  maintained  in  good  mechanical  order.  Regular  sweeping  means at  least  once  per  year  for  smokeless 

fuel and a minimum of twice per year for other fuels. 

 

If the chimney  was previously used for an open fire, it is possible that the higher flue gas temperatures 

generated by the stove may loosen deposits that were firmly adhering to the inner surface of the chimney 

and  cause  blockage  of  the  fluepipe.  We  recommend  that  in  such  a  situation  a  second  sweeping  of  the 

chimney should be carried out within one month of regular use of the stove after installation. Also, lock 

or remove any existing dampers in the flueway. 

 

Should it be likely that children, aged or infirm people approach the fire, then a fireguard should be fitted. 

 

Avoid the use of aerosol sprays in the vicinity of the stove when it is in operation. 

 

This  appliance  must  be  installed  as  per  these  instructions  and  regulations  complied  with.  No 

modifications or alterations of any kind are permitted. 

CONTENTS 

GENERAL SAFETY NOTES 

Summary of Contents for SELBORNE 5 SE

Page 1: ...may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Liter...

Page 2: ...at output Refer to Building Regulations Document J a purpose provided air vent is not normally required However in certain circumstances a purpose provided air vent may be necessary for example small...

Page 3: ...d fuel Be a minimum 4 6m high from hearth level to pot Be terminated at least 1m above roof level so that the chimney does not terminate in a pressure zone see Fig 2 Be free from cracks severe bends v...

Page 4: ...This test is only a guide as an apparently poor flue may improve once the stove is installed lit and the flue is warmed If once the stove is installed there is any doubt that the chimney is providing...

Page 5: ...5 The burning rate of the stove can now be regulated by the rate at which fuel is added and by adjusting the air wash control With the above in mind it is plain to see that the stove should ideally be...

Page 6: ...ignites may cause a chimney fire Resinous softwood burns well and gives a high output for short periods but is not as efficient and does not last as long as hardwood CORRECT RUNNING TEMPERATURE FOR B...

Page 7: ...must be presented The guarantee is 1 year from date of purchase The guarantee does not cover parts that are deemed to be replacable through normal usage of the stove These include glass panels rope s...