Unvented hot water cylinder – SCxn…d/i, SCxn…sd/si 
 

 
 

Page 8 of 28 

ST0109 – C 05/09 

 
 

WATER 

Feature 

SCxn 

si 

sd 

80  

305 

80 

130 

150 

175 

215 

255 

305 

175 

305 

175 

305 

Materials 

 

- inner cylinder 

- outer cylinder 

- inlet/outlet 

- coils 

- insulation 

Duplex stainless steel 

Dove grey leather grain coated steel 

Stainless steel 

Corrugated stainless steel 

60mm PU foam (GWP=1, ODP=0) 

Maximum operating conditions 

- potable water temperature 

- heating water temperature 

- operating pressure 

 

70°C 

95°C 

6bar 

Cold water supply 

- minimum dynamic pressure 

- maximum pressure 

-  minimum flow rate 

 

1.5bar 

25bar 

15 l/min 

Connections 

- cold water inlet 

- hot water outlet 

- secondary return 

- coil flow and return 

- sensor pocket 

 

22mm stainless steel 

22mm stainless steel 

½”F BSP 

22mm stainless steel 

½”F BSP 

Coil specification 

- surface area [m²] 

- rating [kW] 

 

 

0.3 

 

0.5 

14 

 

0.75 

17 

 

0.75/1.1 

17/- 

Immersion heater 

1/

1 1 

Thermostatic control 

- direct input 

- indirect input 

 

- integral immersion heater thermostat and cut out 

- external twin thermostat and cut out 

Safety components 

- pressure reducing valve and 

strainer 

-  expansion relief valve 

- temperature and pressure relief 

valve 

- factory pressure test 

 

2bar 

 

6bar 

7bar / 90°C 

 

10bar 

 

3bar 

 

6bar 

7bar / 

90°C 

10bar 

Other features 

Water inlet diffuser – prevents cold and hot water from mix-

ing 

Water outlet sloped – improves stratification during draw off 

and reduces heat loss 

Light weight – easy handling 

No anode – reduced service requirements 

Approvals 

KIWA 

BBA 

Guarantee 

- inner cylinder 

- immersion heaters 

- other components 

 

25 years 

2 years – excluding the effects of lime scale 

5 years – excluding expansion vessel membrane pressure 

Figure 4 – Product features 

Summary of Contents for SCxn150d

Page 1: ...Page 1 of 28 ST0109 C 05 09 WATER Unvented hot water cylinder SCxn d i SCxn sd si Installation and operating instructions...

Page 2: ...ge 2 of 28 ST0109 C 05 09 WATER 0 Overall view Figure 1 Overall view of proposed installation sequence SCxn d i SCxn80 130 150 175 215 255 305d 01 02 03 04 05 06 07 SCxn80 130 150 175 215 255 305i 11...

Page 3: ...3 of 28 ST0109 C 05 09 WATER Figure 2 Overall view of proposed installation sequence SCxn sd si SCxn175 215 255 305sd SCxn175 215 255 305si 18 01 02 03 04 05 07 08 09 10 11 12 13 14 15 16 17 18 01 02...

Page 4: ...DISCHARGE PIPE WORK 10 5 4 HOT WATER OUTLET 12 5 5 IMMERSION HEATER 12 5 6 INDIRECT HEATING LOOP 13 5 7 SOLAR LOOP 14 5 8 SECONDARY RETURN 15 5 10 INSTALLATION EXPANSION VESSEL 15 5 11 WIRING SCHEMAT...

Page 5: ...ent person as defined in the relevant regulations Dimplex does not accept any liability for damage done to persons or property resulting from undue handling and usage of this product All regulations c...

Page 6: ...rne organisms i e Legionella if applicable a risk assessment should be carried out following the recommendations outlined in the Approved Code of Practise L8 the user preference must be considered whe...

Page 7: ...storage volumes from 80 litres to 305 litres in various designs from direct electric heated units indirect units to a range of units allowing the use of renew able energy sources such as solar therma...

Page 8: ...steel F BSP 22mm stainless steel F BSP Coil specification surface area m rating kW 0 3 7 0 5 14 0 75 17 0 75 1 1 17 Immersion heater 1 2 1 1 2 Thermostatic control direct input indirect input integral...

Page 9: ...eference Handling depending on the size of the unit and access to its installation location con sideration must be given to the handling of the unit Please note that handling installa tion and use of...

Page 10: ...correctly insulated to avoid frost damage If required the occurrence of frost has to be avoided by means of heating the space in which the cylin der is located 5 3 Cold water supply and discharge pipe...

Page 11: ...necessary Note Between the inlet group and the cold water inlet on the cylinder NO isolating device should be fitted as by doing so important safety devices could be isolated 6 The temperature and pre...

Page 12: ...providing hot water 5 5 Immersion heater The immersion heater has to be connected in accordance with IEE Wiring Regulations and the installer carrying out the work has to be suitably qualified It mus...

Page 13: ...heating source can be connected to the cylinder in various ways as de scribed by the chosen control system supplier The wiring and installation principles for two typical integration methods are deta...

Page 14: ...valve ensure the direction of flow is adhered to as marked on the body of the device Connecting the control loop ensure the correct thermostat on the cylinder is chosen for the respective loop The fit...

Page 15: ...be installed in the lowest point 5 8 Secondary return A boss is provided on the SCxn sd si cylinder range to connect a secondary return loop to avoid stagnant water in long pipe runs long waiting time...

Page 16: ...he pre charge pressure of the expansion vessel mem brane before filling the cylinder The pre charge should be 2bar 5 11 Wiring schematic auxiliary loop The auxiliary heating system can be interfaced w...

Page 17: ...Unvented hot water cylinder SCxn d i SCxn sd si Page 17 of 28 ST0109 C 05 09 WATER Figure 11 Auxiliary loop integration 2x motorised two port valve...

Page 18: ...Unvented hot water cylinder SCxn d i SCxn sd si Page 18 of 28 ST0109 C 05 09 WATER Figure 12 Auxiliary loop integration 1x motorised two port valve and mid position valve...

Page 19: ...SCxn range cylinders allow for the installation of two sensors The lower sensor is required to control the solar circulation pump The upper sensor is for information only to indicate the actual availa...

Page 20: ...Unvented hot water cylinder SCxn d i SCxn sd si Page 20 of 28 ST0109 C 05 09 WATER Figure 14 Solar sensor boss positions and sensor installation 01 02 03...

Page 21: ...ed 9 Remove the pump and replace the blue cap 10 Turn the mains supply back on and bring the cylinder up to working pressure 11 Check all joints for leaks even those not having been altered especially...

Page 22: ...nuals and bench mark card advising the owner of annual service requirement 7 Operation Once the system has been fully commissioned no user interference should be required to fully enjoy the comfort an...

Page 23: ...electrical supplies from the unit before commencing work Danger of electrical shock 1 Draw some water from cold water tap and retain in container 2 Isolate cold water mains supply from cylinder 3 Bri...

Page 24: ...is charge through tun dish on warm up C 1 Bubble depleted C 2 Expansion vessel lost charge C 1 See commissioning for creation of bubble C 2 Check expansion vessel see commission ing maintenance top up...

Page 25: ...5 65 Heat loss kWh d i 1 12 1 50 1 82 2 10 2 59 2 73 2 88 Heat up mns d 64 115 138 167 212 263 313 i 33 28 33 27 35 42 50 Re heat mns d 53 90 104 124 153 184 220 i 23 21 24 24 30 35 42 A mm d i 182 B...

Page 26: ...d 20 24 29 34 si 18 22 25 30 Re heat mns sd 14 17 20 24 si 13 18 19 22 A mm sd si 182 B mm sd si 531 589 C mm sd 846 1087 1355 1631 D N P mm sd si 1017 1259 1527 1804 E mm sd si 1243 1485 1753 2029 F...

Page 27: ...Unvented hot water cylinder SCxn d i SCxn sd si Page 27 of 28 ST0109 C 05 09 WATER...

Page 28: ...SCxn d i SCxn sd si Page 28 of 28 ST0109 C 05 09 WATER Dimplex UK Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Te 01489 773 052 Fax 01489 773 061 e mail customer services dimpl...

Reviews: