background image

Montage- und
Gebrauchsanweisung

Installation and

Operating Instructions

D

e

u

ts

c

h

F

ra

n

c

a

is

E

n

g

lis

h

F

ra

n

c

a

is

Instructions de
montage et d‘utilisation

Wandkonvektor

Bestell-Nr. / Order no. / No de commande: INDPGEP5RG                                                                                07/14/B

Convecteur de Base 
Mural

PLX 500
PLX 750 
PLX 1000
PLX 1500
PLX 2000 TI
PLX 2500
PLX 3000

Convector heater

Summary of Contents for PLX 1000

Page 1: ...nstructions Deutsch Francais English Francais Instructions de montage et d utilisation Wandkonvektor Bestell Nr Order no No de commande INDPGEP5RG 07 14 B Convecteur de Base Mural PLX 500 PLX 750 PLX 1000 PLX 1500 PLX 2000 TI PLX 2500 PLX 3000 Convector heater ...

Page 2: ...flichtig anerkannter Mängel geschied dadurch dass die mangelhaften Teile unentgeldlich nach unserer Wahl instantgesetzt oder durch einwandfreie Teile ersetzt werden Durch Art oder Ort des Einsatzes des Gerätes bedingte au ßergewöhnliche Kosten der Mängelbeseitigung werden nicht über nommen Der freie Gerätezugang muss durch den Endabnehmer gestellt werden Ausgebaute Teile die wir zurücknehmen gehen...

Page 3: ...l description EN 9 3 Mounting Installation Minimum clearances EN 9 3 1 Wall mounting EN 9 4 Electrical connection EN 9 5 Heater operation EN 10 5 1 Heaters without timers EN 10 5 2 Thermostat EN 10 5 3 Heaters with Timer EN 10 6 Overheat Protection EN 10 7 Malfunctions EN 10 8 Cleaning EN 11 9 Technical Data EN 11 10 Customer Service Spare Parts Warranty EN 11 11 Disposal EN 11 1 Consignes pour I ...

Page 4: ... Verbrennungen verursachen Besondere Vorsicht ist geboten wenn Kinder oder schutzbedürftige Personen anwesend sind ACHTUNG Die Anschlussleitung nicht über das Gerät legen Gerät niemals in Betrieb nehmen wenn Gerät oder Netz leitung beschädigt sind Lebensgefahr ACHTUNG Das Gerät darf nicht unter einer Wandsteck dose aufgestellt werden ACHTUNG Wenn das Netzkabel beschädigt ist muss es vom Hersteller...

Page 5: ...ter muss verwendet werden Entfernen Sie den Wandhalter von der Rückseite des Gerätes durch Drücken der Federn an jeder Seite Befestigungslöcher bohren Ach ten Sie hierbei auf sich in der Wand befindliche Elektro oder Rohrleitungen Den Wandhalter mit den beiliegenden Schrauben fest an der Wand verschrauben Hängen Sie das Gerät in die unteren Schlitze der Wandhalterung ein Bringen Sie das Gerät in e...

Page 6: ...rsinn drehen bis die aktuelle Uhrzeit an der Markierung steht Heizgerät EIN Segmente nach außen schieben Heizgerät AUS Segmente nach innen schieben Jedes Segment entspricht einer Ein oder Ausschalt dauer von 20 Minuten Um z B eine Einschaltdauer von 2 Stunden einzustellen werden 6 Segmente nach außen geschoben Die Schaltuhr kann für mehrere EIN AUS Phasen mit unterschiedlichen Längen programmiert ...

Page 7: ...ulmbach Technische Änderungen vorbehalten 9 Technische Daten 10 Entsorgungshinweis Das Gerät nicht im allgemeinen Hausmüll ent sorgen sondern einer örtlichen Entsorgungs stelle zuführen Telefon 49 9221 709 564 Telefax 49 9221 709 589 Email 09221709589 dimplex de www dimplex de Anschlussspannung 1 N PE 230V 50Hz Temperaturregler 6 30 C Schutzklasse Schutzleiteranschluss Schutzart IP X4 spritzwasser...

Page 8: ...ified persons in order to avoid a hazard ATTENTION The heater must not be located beneath a socket outlet ATTENTION In order to avoid overheating do not cover the heater ATTENTION Do not use the appliance in room with bath shower or swimming pool or in the vicinity of wash basins or water connections ATTENTION The heater carries the warning symbol indicating that it must not be covered To ensure s...

Page 9: ...g bracket sup plied located at the back of the heater must be used Remove the bracket from the back of the device by pressing the springs on each side Drill the fixing holes for the wall mounting bracket Firmly secure bracket to the wall using suitable screws Insert heater in wall bracket making use of the slots on the back of the heater Snap heater in place at the top of the wall bracket 4 Electr...

Page 10: ...manually i e without timer Position means automatic operation i e the con vector is switched on and off automatically by the timer The thermostat ensures a uniform room temperature during the operation duration No heating operation takes place outside the pre set operating time frost protection is also deactivated Setting the clock Rotate the timer s dial in clockwise direction until the current t...

Page 11: ...ge the surface Dust that may have accumulated in the heater can be removed from the outside with a vacuum cleaner Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D 95326 Kulmbach Subject to modifications without prior notice 9 Technical Data 10 Customer Service Spare Parts Warranty Please contact your local dealer for information on customer service and warranty conditions The warranty is not va...

Page 12: ...bricant ou son représentant S A V ou par une personne à qualification comparable afin d éliminer les sources de danger ATTENTION Il est interdit de poser l appareil sous une prise murale ATTENTION Pour éviter la surchauffe l appareil ne doit pas être couvert ATTENTION Ne pas couvrir l appareil de chauffage risque d incendie ATTENTION Il faut installer l appareil de sorte que les organes de command...

Page 13: ...er une distance minimum de 500 mm 3 1 Montage mural ATTENTION Il faut utiliser la fixation murale d origine livrée avec l appareil et située au dos de celui ci Percer les trous pour la fixation murale Visser la fixation solidement au mur Suspendre l appareil à la fixation murale au moyen des fentes situées au dos de l appareil Encliqueter le haut de l appareil sur la fixation mu rale 4 Branchement...

Page 14: ...s arrête automatiquement sous la commande de l in terrupteur horaire Le thermostat assure une tempéra ture ambiante constante pendant la durée totale de fonctionnement Aucun chauffage et aucune protection antigel n inter viennent en dehors de la durée de fonctionnement Régler l heure Tourner l interrupteur horaire dans le sens des aiguilles de la montre jusqueà ce que l heure actuelle appa raisse ...

Page 15: ... le service après vente 8 Nettoyage Pour le nettoyage l appareil doit être isolé du secteur et avoir refroidi La face extérieure se nettoie avec un chiffon doux et humide N utilisez pas de poudre à ré curer ou d encaustique qui risqueraient d endommager la surface La poussière qui s accumule dans l appareil peut être aspirée depuis l extérieur 9 Caractéristiques techniques 10 Service après vente g...

Page 16: ...PLX 750 PLX 1000 PLX 1500 PLX 2000TI PLX 2500 PLX 3000 Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D 95326 Kulmbach Sous réserve de modifications techniques Téléphone 49 9221 709 564 Télécopie 49 9221 709 589 Email 09221709589 dimplex de www dimplex de fr ...

Reviews: