background image

The wall plate is secured to the chassis with 2 screws (see

Fig.4 

detail

 ‘X’

,’

1’

). To wall mount the appliance first remove

the wall plate from the chassis by removing the two screws
and rotating the corner hinges away from the chassis.
Note : Retain the two screws for future use.

Fix the wall plate to the wall using the wall plugs and screws
provided. (Note: Ensure that the wall is suitable for the screws
& plugs provided).

Use the wall plate as a template to mark the hole positions
for drilling - see 

Fig.2

.  Drill and fix the wall plate in position

with one screw initially to check the plate is level before
marking and drilling the remaining holes.
Ensure the wall plate is fitted the correct way up i.e. the side
hooks are pointed upwards. - see 

Fig.3

.

The appliance can then be hung on the wall plate by aligning
the slots on the chassis with the side hooks on the wall
plate.

Check to ensure that the bottom hooks have also engaged
in their respective slots.

The corner hinges on the wall plate may be used to secure
the appliance against inadvertent dislodgement. Simply
rotate the the hinges upwards to a position above the chassis
(see 

Fig.2

 and 

Fig.3

). They can then be screw fixed using the

screws removed earlier (see 

Fig.4

, detail 

‘X’, ‘1’

).

NOTE: The appliance should be hard wired to a fused
switched spur located behind the glass panel so as to be
hidden from view (see  

Fig. 1, ‘b’

). The programme compact

flash memory card is factory fitted and protected by a screw
fixed security cover, ( see 

Fig.4 ‘a’

) In normal use access to

the card is not a requirement.

Please consult a qualified electrician for appropriate wiring
requirements.

Operation: - LVA192 - LVA192NH

Plug in the IEC connector from the hard wiring outlet to the
IEC fused (SSC 10A 250V) socket on the appliance (see

Fig.1

, detail 

A,1

).

The illuminated power ‘On’ switch (see 

Fig.5

 detail 

‘Z’, 1

)

must first be switched 

‘ON’

 to operate the appliance.

One of the scenes will automatically show when the power

‘ON’

 switch is operated.

Scene selection and sound control can now be acheived
manually or by remote control, see instructions below.

Note: The user may notice a slight frame freeze lasting less
than 0.5 seconds after a scene has run for approximately 5
minutes. This is normal and should not be a cause for
concern.

Twin fan heaters positioned one left, one right behind the
glass can be operated manually by switch(see 

Fig.5

 detail ‘

Z’, 2

) or by the remote control. Fan operation is indicated by a

red light, which will remain lit while the fans are in use, (see

Fig.1

 detail

 B, 1

). Each fan heater has an individual element

switch (see 

Fig.1

 detail 

C

)

 

this provides for cold blow operation

if heat is not required.

 (LVA192 Only)

 .

Manual Control Operation: - LVA192 - LVA192NH

The manual controls for the screen are located at the top of
the appliance behind the glass screen (see

 Fig.4, 

detail 

‘Y’

).

The membrane switch functions are as described below;

              Standby Switch 

‘On’

 / 

‘Off’

 a red light indicates

standby mode. (See 

Fig.1

 detail 

B,2

)

Sound Volume ‘Up’

Sound Volume ‘Down’

Scene Selection ‘Up’

Scene Selection ‘Down’

The manual switch for the fan heaters, (see 

Fig.5

 detail 

‘Z’

,

2

). Each fan heater has an element switch to provide the

option of hot or cold blow, (see 

Fig.1

. detail 

C

). 

(LVA191 Only)

The appliance Illuminated Power switch (see 

Fig.5

 detail 

‘Z’

,

1

) may be used to switch the appliance 

‘OFF’

 when it is not

required, say overnight or for long periods, to avoid energy
wastage.

Remote Control Operation: - LVA192 -
LVA192NH

The remote control may be operated once the appliance is
switched 

‘ON’

 (see 

Fig.5, 

detail

 ‘Z’, 1

).

Aim the remote control at the screen (I.R. sensor is indicated
in 

Fig.1

 detail 

B, 3

) select any one of the eight scenes on your

remote control (see 

Fig.7

)

Each scene has it’s own particular sound effect which may
be activated and adjusted up or down by pressing the  volume

control buttons (

 and 

) until the level required is

reached.

The fan heaters may be switched 

‘ON’

 and 

‘OFF’

 by pressing

the buttons 

 or 

. A red light indicates the fans are in

operation and will remain lit while the fans are 

‘ON’

 (see

Fig.1

 detail

 B, 1

).  

(LVA192 Only)

The button functions are identified as described below;

‘Coal’ Fire scene

‘Log’ Fire scene

‘Embers’ Fire scene

‘Spring’ scene

‘Summer’ scene

‘Autumn’ scene

‘Winter’ scene

‘Aquarium’ scene

        

  

 Fan Heater ‘ON / ‘OFF’. (Hot or Cold blow option

 is by manual selection

 LVA192 only

)

Summary of Contents for LVA192

Page 1: ...complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC Patents pending No 05104792 6 and No 04104794 2 ...

Page 2: ......

Page 3: ...7 6 ...

Page 4: ...IN ORDER TOAVOID OVERHEATING DO NOT COVERTHEHEATER The heater carries the Warning symbol indicating that it must not be covered Living Art Range Model s LVA192 LVA192NH IMPORTANT THESEINSTRUCTIONSSHOULDBEREADCAREFULLYANDRETAINEDFORFUTUREREFERENCE Electrical WARNING THISAPPLIANCE MUST BE EARTHED This appliance must be used on an AC supply only and the voltage marked on the appliance must correspond...

Page 5: ...ontrol see instructions below Note The user may notice a slight frame freeze lasting less than 0 5 seconds after a scene has run for approximately 5 minutes This is normal and should not be a cause for concern Twin fan heaters positioned one left one right behind the glass can be operated manually by switch see Fig 5 detail Z 2 or by the remote control Fan operation is indicated by a red light whi...

Page 6: ... when the appliance is in standby mode See Fig 1 detail B 2 On the LVA192 the fan heaters can be operated when the scenes are in standby if desired and in which case there will be two red lights displayed one indicating the standby mode and the other fan heaters ON See Fig 1 detail B 1 2 Remote Control Assembly Note The remote control is packed separately in the carton 1 Slide open the battery cov...

Page 7: ......

Page 8: ...st Check with your Local Authority or retailer for recycling advice in your country Cleaning WARNING ALWAYS DISCONNECT FROM THE POWER SUPPLYBEFORECLEANINGTHEAPPLIANCE For general cleaning use a soft clean duster never use abrasive cleaners The glass viewing screen should be cleaned carefully with a soft cloth DO NOT use proprietary glass cleaners After Sales Service Your product is guaranteed for ...

Reviews: