www.dimplex.de
E-9
English
12
12 Device Information
1
Type and order code
LAS 10MT
LAS 15MT
LAS 22TT
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices and
heating components
IP 24
IP 24
IP 24
2.2
Installation location
Outdoors
Outdoors
Outdoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow / return flow
1
°C / °C
1. See operating limits diagram
Up to 40 / above 10
Up to 40 / above 10
Up to 40 / above 10
Air
°C
-10 to +35
-10 to +35
-10 to +35
3.2
Heat output / COP at
A20 / W24
2
kW / -
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. E.g. A20 / W24 have the following meaning: external air temperature 20°C and swimming
pool flow temperature 24 °C.
12.1 / 4.2
16.6 / 4.7
22.3 / 5.1
3.3
Sound power level
dB(A)
70
70
71
3.4
Sound pressure level
at a distance of 10 m (air outlet side)
dB(A)
45
45
46
3.5
Pool water flow with an internal pressure differential of
m³/h / Pa
1.6 / 7200
2.0 / 12000
2.5 / 8000
3.6
Refrigerant; total filling weight
type / kg
R407C / 1.5
R407C / 1.6
R407C / 2.5
3.7
Lubricant; total filling weight
type / litres
FV68S / 1.7
FV68S / 1.7
FV68S / 1.7
3.8
El. output of defrost heater
kW
1.8
2.4
3.0
4
Dimensions, connections and weight
4.1
Device dimensions
H x W x L cm
86 x 127 x 67
86 x 127 x 67
86 x 127 x 67
4.2
Device connections to heating system
Inch
G 1'' external
G 1'' external
G 1 1/2'' external
4.3
Weight of the transportable unit(s) incl. packing
kg
147
155
162
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
230 / 20
230 / 25
400 / 16
5.2
Nominal power consumption
2
A15 / W32
kW
3.3
4.0
5.1
5.3
Starting current with soft starter
A
33
43
25
5.4
Nominal current
A15 / W32 / cos
M
A / ---
17.0 / 0.8
21.0 / 0.8
10.0 / 0.8
6
Complies with the European safety regulations
3
3. See CE declaration of conformity
3
3
7
Additional model features
7.1
Defrosting
Automatic
Automatic
Automatic
Type of defrosting
Electrical
Electrical
Electrical
Defrosting tray included
Yes (heated)
Yes (heated)
Yes (heated)
7.2
Heating water in device protected against icing
4
4. Continuous operation of the filter pump must be ensured on-site and the heat pump controller must be ready for operation.
Yes
Yes
Yes
7.3
Performance levels
1
1
1
Summary of Contents for LAS 10MT