IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Important Safety Advice  

Please read these instructions carefully before installing 

or using this appliance. Failure to do so may result in 

damage to persons and property. 

Installation  of  this  appliance  must  be  carried  out  by  a 

suitably qualified competent person in accordance with 

all Building Regulations, including those referring to 

Local 

Authority Bye-Laws, National and European Standards 

and Codes of Practice.

Do not install this appliance on a shared flue.

This appliance operates at very high temperatures and 

retains its heat for a period after use. Do not touch any 

surfaces while in use. All persons including children and 

the infirm should be warned of this and not allowed to 

touch any surfaces while in use. Please use a suitable 

fireguard to prevent contact when in use. 

Do not place any photographs, paintings, TV’s or other 

combustible  items  near  the  appliance  as  exposure  to 

hot surfaces will cause damage. Maintain safe distances 

from combustibles in all cases in accordance with these 

instructions – please refer to installation.

The  operator  must  use  the  tools  provided.  The  mitten 

provided is a tool.

Do  not  fit  an  extractor  fan  in  the  same  room  as  this 

appliance.

Ensure that there is adequate ventilation in the room in 

accordance with building standards. Do not obstruct any 

of the air inlets or outlets on the appliance. 

A flue damper should not be fitted when burning solid 

fuels other than wood.

This  appliance  is  for  domestic  heating  use  only  in 

accordance  with  these  operating  instructions.  Do  not 

make any unauthorised changes to the appliance.

Only use recommended fuels. Do not burn petroleum coke 

fuels, household waste or plastic in this appliance.

Burn only fuels with a low moisture content - burning soft 

or wet fuels such as unseasoned timber or peat will only 

result in a build up of tar in the stove and the chimney 

and will cause staining of the glass.

Do not use flammable liquids to ignite the fire.

Avoid the use of aerosols in the vicinity of the stove when 

it is in operation.

Clean your chimney at least twice a year and clean the 

flue way weekly to ensure there are no blockages. Do not 

allow a build up of ash to occur in the ash pan as this will 

cause the grate to burn out prematurely.

Regular  maintenance  should  be  carried  out  by  a 

Competent Engineer.

Health and Safety Precautions

Handling:

 

Adequate facilities must be available for the unloading 

and handling of this appliance. This product is heavy and should 

be handled with care. When handling or servicing this stove care 

should be taken to avoid the possibility of personal injury. Use 

protective clothing.

Fire Cement/Glue:

 

Some types of fire cement/glue are caustic 

and should not be allowed to come into contact with the skin. Use 

suitable protective gloves when handling. In case of contact, wash 

immediately with plenty of water.

Asbestos: 

This  appliance  contains  no  asbestos.  If  there  is  a 

possibility of disturbing asbestos as a result of installation then 

specialist guidance must be sought prior to installing. 

Installation Instructions

General

These instructions give a guide for the installation of the stove but 

in no way absolves the installer from responsibilities to conform 

to all relevant standards relating to the installation of solid fuel 

appliances. 
We  recommend  that  for  UK  installations  a  HETAS  registered 

installer should be used, who will be able to give a Certificate of 

Compliance that installation complies with Building Regulations. 

In Ireland a registered installer from the Irish Nationwide Fireplace 

Organisation should be used. 
Please note that to the best of our abilities these instructions are 

correct at time of printing, however we cannot be held responsible 

for any differences in legislation which may occur in the future.

Assembly of the stove 

To make the product easier for handling on installation, remove 

the baffle plate, side bricks, back brick and ashpan. Place these 

in a secure place to avoid damage. These must be refitted after 

installation. The legs and other fixings are packed in the ashpan 

for safe keeping in transport. Fix the legs to the underside of the 

product using the bolts provided 

(Fig 2)

The  stove  is  supplied  ready  for  rear  flue  connection.  For Top 

flue connection 

(Fig 3) 

remove the flue cap from the top plate by 

removing the screws on underside of top plate inside the stove. 

Reposition the flue cap on the rear flue outlet and tighten all fixing 

screws to ensure it is air tight. 

Chimney

Before installing, check the chimney is in good condition; dry and 

free from cracks and obstructions. The diameter of the chimney 

flue should not be less than 150mm and not more than 230mm. 

If any of these requirements are not met, the chimney should be 

lined by a suitable method by a qualified person.
The chimney height and the position of the chimney terminal should 

conform to Building Regulations. If you have any doubts about the 

suitability if your chimney, consult your local dealer or stockist. The 

chimney must be swept before connection to the stove and swept 

every six months thereafter.
If there is no existing chimney then either a prefabricated block 

chimney or a twin walled insulated stainless steel flue to BS4543 

can be used. These chimneys must be fitted in accordance with 

the manufacturers instructions and in compliance with Building 

Regulations.

This product must not be installed on a shared flue.

Langbrook 5kW Clean Burn Stove (LBK5SE)

- 1 -

Summary of Contents for Langbrook LBK5SE

Page 1: ...may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Liter...

Page 2: ...lation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation should only be carried out by a suitably qualif...

Page 3: ...Wood kW 5 0 Solid Fuel Ancit kW 5 0 Efficiency Wood 77 0 Solid Fuel Ancit 78 4 CO Emission 13 O2 Wood 0 32 Solid Fuel Ancit 0 23 Flue Gas Temp Wood C 306 Solid Fuel Ancit C 274 Flue Gas Mass Flow Woo...

Page 4: ...T Min Wall height H 0mm 0 50mm 200mm Height of appliance 300mm or 1200mm from hearth whichever is greater 0mm 51 150mm 75mm 0 150mm 150 300mm 75mm 150mm 300mm No Minimum Requirement H MIN 150mm X X T...

Page 5: ...150 max Seal gap with fire proof lagging 150 max CLOSURE PLATE SEAL C D B A 10 8 9 7...

Page 6: ...ty of personal injury Use protective clothing Fire Cement Glue Some types of fire cement glue are caustic and should not be allowed to come into contact with the skin Use suitable protective gloves wh...

Page 7: ...minimum thickness12mm Fig 5 shows the minimum distances required from the hearth edge to the sides of the stove 2 In all cases allow an apron of at least 300mm at the front of the stove in case of spi...

Page 8: ...cause poor operation and can cause excessive smoke to occur on ignition The stove must not be operated with the appliance door left open The stove can be banked up for long periods When burning solid...

Page 9: ...ld up of soot on the baffle plate the plate inside the stove above the grate it must be removed and cleaned periodically This plate locates the back and side firebricks so note its position before rem...

Page 10: ...the guarantee that the installation complies with relevant Building Regulations and is carried out by a suitably qualified individual HETAS registered in England and Wales or equivalent in other coun...

Page 11: ......

Page 12: ...SS FIXING BKT 3011108 22 DOOR CATCH 3011123 8 GRATE OUTER 3011109 23 FOOT 2 FRONT RH 3011124 9 GRATE INNER LH 3011110 24 FOOT 1 FRONT LH 3011125 10 GRATE INNER RH 3011111 25 FOOT 3 REAR RH 3011126 11...

Page 13: ...is publication may not be reproduced in whole or in part without prior permission in writing of GDC Group Ltd DIMPLEX MILLBROOK HOUSE GRANGE DRIVE HEDGE END SOUTHAMPTON SO30 2DF TEL 0845 600 5111 FAX...