EN-10 452168.66.01 · FD 9512
www.dimplex.de
English
LA 9S-TU(R) - LA 18S-TU(R)
12 Device information
1
Type and order code
LA 9S-TU
LA 12S-TU
LA 18S-TU
2
Design
Heat source
Air
Air
Air
2.1
Model
Universal
Universal
Universal
2.2
Controller
WPM Econ 5S, wall-
mounted
WPM Econ 5S, wall-
mounted
WPM Econ 5S, wall-
mounted
2.3
Installation location
Outdoors
Outdoors
Outdoors
2.4
Thermal energy metering
Integrated
Integrated
Integrated
2.5
Performance levels
1
1
2
3
Operating limits
3.1
Heating water flow / return
1
°C
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
3.2
Air (heating)
1
°C
-22 to +35
-22 to +35
-22 to +5
2
/ +35
3
4
Flow
4
/ sound
4.1
Heating water flow / internal pressure differential
Nominal flow in accordance with EN 14511
at A7 / W35...30
m³/h / Pa
1,5 / 9900
1,9 / 17800
1,5 / 10000
at A7 / W45...40
m³/h / Pa
1,4 / 8800
1,8 / 16800
1,4 / 8900
at A7 / W55...47
m³/h / Pa
0,9
5
/ 3600
1,2
5
/ 6100
1,4
5
/ 3700
4.2
Minimum heating water flow rate
m³/h / Pa
1,2 / 6400
1,4 / 10000
1,4 / 8900
4.3
Sound power level according to EN 12102
Normal operation / reduced operation
6
7
dB(A)
53 / 53
54 / 53
54 / 53
4.4
Sound pressure level at a distance of 10 m (air outlet side)
8
Normal operation / reduced operation
6
7
dB(A)
25 / 25
26 / 25
26 / 25
4.5
Air flow
Normal operation / reduced operation
7
m³/h
2700 / 2100
4700 / 3600
5500 / 3200
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
H x W x L mm
1650 x 910 x 750
1650 x 910 x 750
1650 x 910 x 750
5.2
Device connections for heating
inches
G 1 1/4" external thread G 1 1/4" external thread G 1 1/4" external thread
5.3
Weight of the transportable unit(s) incl. packaging
kg
225
265
295
5.4
Refrigerant / total filling weight
type/kg
R410A / 3.9
R410A / 4.78
R410A / 5,9
5.5
Lubricant / total filling quantity
type/litres
Polyolester (POE)/1.2
Polyolester (POE)/1.2
Polyolester (POE)/1.2
5.6
Volume of heating water in device
Litres
2.6
3.8
3.8
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C13 A / A
6.2
Control voltage / fusing by WPM
1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
6.3
Degree of protection according to EN 60529
IP 24
IP 24
IP 24
6.4
Starting current limiter
Soft starter
Soft starter
Soft starter
6.5
Rotary field monitoring
Yes
Yes
Yes
6.6
Starting current with soft starter
A
21
19
21
6.7
Nominal power consumption A2/W35 /
max. power consumption
4
kW
1,7 / 3.3
2,38 / 4,0
3,24 / 6,8
6.8
Nominal current A2 /W35 / cos
A / ---
3,1 / 0,8
4,3 / 0,8
5,9 / 0,8
6.9
Power consumption of compressor protection
(per compressor)
W
70 / thermostatically
controlled
70 / thermostatically
controlled
70 / thermostatically
controlled
6.10 Power consumption of fan
W
up to 100
up to 150
up to 200
7
Complies with the European safety regulations
9
9
9
8
Additional model features
8.1
Type of defrosting
Reverse circulation
Reverse circulation
Reverse circulation
8.2
Frost protection, condensate tray /
Water in device protected against freezing
10
Yes
Yes
Yes
8.3
Maximum operating pressure (heat sink)
bar
3.0
3.0
3.0
8.4
Energy efficiency class / energy efficiency (low temperature)
A++ / 172 %
A++ / 167 %
A++ / ^179 %
8.5
Energy efficiency class / energy efficiency (mean temperature)
A++ / 125 %
A++ / 125 %
A++ / 130 %
9
Heat output COP
4