LA 11TAS - LA 16TAS
11 Device information
1
Type and order code
LA 11TAS
LA 16TAS
2
Design
2.1
Manager
External
External
2.2
Installation location / degree of protection according to EN 60529
Outdoor / IP24
Outdoor / IP24
2.3
Antifreeze condensate tray / heating water
Heated / yes
1
1. The heat circulating pump and the heat pump manager must always be ready for operation.
Heated / yes
1
2.4
Performance levels
1
1
3
Operating limits
3.1
Heating water flow / return
°C
up to 58 ± 2 / from 18
up to 58 ± 2 / from 18
Air (heat source)
°C
-25 to +35
-25 to +35
4
Performance data / flow rate
2
2. These data indicate the size and capacity of the system according to EN 14511 (5K at A7). For an analysis of the economic and energy efficiency of the system, other parameters,
in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration. These specifications can only be achieved with clean heat
exchangers. Information on the maintenance, start-up and operation can be found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
4.1
Heating water flow rate / internal pressure differential
maximum
m³/h / Pa
1.9 / 9200
2.6 / 11900
minimum
m³/h / Pa
1.3 / 4100
1.7 / 6300
4.2
Heat output / COP
3
3. With maximum heating water flow.
EN 14511
EN 14511
at A-7 / W35
kW / ---
7.2 / 2.8
10.0 / 2.7
at A2 / W35
kW / ---
8.6 / 3.4
11.7 / 3.2
at A7 / W35
kW / ---
10.1 / 4.0
14.6 / 3.7
at A7 / W55
kW / ---
10.3 / 2.7
14.4 / 2.7
at A10 / W35
kW / ---
11.3 / 4.4
16.6 / 3.9
4.3
Sound power level according to EN 12102
Normal operation/reduced operation
4
dB(A)
4. The heat output is reduced by approx. 5 % in lower operation
59 / 57
62 / 60
4.4
Sound pressure level at a distance of 10 m(air outlet side)
5
Normal operation/reduced operation
dB(A)
5. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
31 / 29
32 / 30
4.5
Air flow
m³/h
2500
4000
5
Dimensions, connections and weight
5.1
Device dimensions without connections
H x W x L mm
1340 x 852 x 1050
1550 x 852 x 1074
5.2
Device connections for heating system
Inches
R1“
R1“
5.3
Weight of the transport unit(s) incl. packaging
kg
193
231
5.4
Refrigerant; total filling weight
type / kg
R404A / 2.5
R404A / 3.5
5.5
Lubricant; total filling quantity
type / litres
Polyolester (POE) / 1.5
Polyolester (POE) / 1.9
6
Electrical connection
6.1
Supply voltage; fuse protection
3~/PE 400 V (50 Hz) / C13 A
3~/PE 400 V (50 Hz) / C13 A
6.2
Control voltage; fuse protection
- /-
- /-
6.3
Starting current with soft starter
A
15
20
6.4
Nominal power consumption
A2 W35/ max. power consumption
3
kW
2.50 / 4.1
3.66 / 6.4
6.5
Power consumption ventilator
W
up to 85
up to 180
6.6
Nominal current A2 W35 / cos
A / ---
4.51 / 0.8
6.60 / 0.8
7
Complies with the European safety regulations
6
6. See CE declaration of conformity
6
8
Additional model features
8.1
Type of defrosting
Reverse circulation
Reverse circulation
8.2
Max. operating overpressure (heat sink)
bar
3,0
3,0
Summary of Contents for LA 11TAS
Page 2: ......
Page 14: ...DE 12 452164 66 01 FD 9602 www dimplex de Deutsch LA 11TAS LA 16TAS ...
Page 53: ...www dimplex de 452164 66 01 FD 9602 A XIX Anhang Appendix Annexes LA 11TAS LA 16TAS ...
Page 54: ...A XX 452164 66 01 FD 9602 www dimplex de Anhang Appendix Annexes LA 11TAS LA 16TAS ...
Page 55: ...www dimplex de 452164 66 01 FD 9602 A XXI Anhang Appendix Annexes LA 11TAS LA 16TAS ...