Dimplex Indoor Electric Fireplace Practical User'S Manual Download Page 5

MAINTENANCE

 

WARNING 

• 

Disconnect all power coming to fireplace 
at main service panel before attempting 
any maintenance or cleaning to reduce risk 
of fire, electric shock or damage to  
persons 

Light Bulb Replacement:

Light bulbs need to be replaced when you notice a dark section of the
flame.  There are two bulbs which generate the flames and embers.

Tool Requirements:

  Slot Screw Driver

Bulb Requirements:  

Quantity of 2 clear chandelier or candelabra

bulbs with an E-12 (small) socket base, 60 watt rating.  Example: GE
60BC or Philips 60CTC.

Helpful Hints

It is a good idea to replace all light bulbs at one time if they are close to
the end of their rated life.  Group replacement will reduce the number
of times you need to open the unit to replace light bulbs.  Long life
bulbs are recommended to reduce the frequency of bulb changes.

 

NOTE 

• 

Allow at least 5 minutes for light bulbs to 
cool off before touching bulbs to avoid 
accidental burning of skin. 

 

CAUTION 

• 

Do not exceed 60 watts per bulb. 

• 

When handling log only apply force to the 
ember bed section not directly to the logs. 

 

OPERATION

REMOTE CONTROL

The Optiflame fireplace is
supplied with a radio
frequency remote control (all
models except BF30E).  This
remote control has a range of
approximately 50ft. (15.25m),
it does not have to be pointed
at the fireplace and can pass
through most obstacles
(including walls).  It is
supplied with one of 243
independent frequencies to
prevent interference with
other units.  The frequency
designation is indicated on
the back of the transmitter
(FIGURE 1).

A. Remote Control

Initialization

This procedure is required
every time there is a loss of
power to the remote control in
the fireplace (i.e. power
failure, breaker tripped, main
power switch is turned off)

1. Ensure that power is supplied through main service panel.
2. Access the manual controls, (remove glass doors if applicable)

pull right hand edge of right hand steel curtain towards the
center of unit.  (FIGURE 2)

3. Locate manual controls refer to FIGURE 3.
4. Activate main power switch, red indicator light 1 will flash.
5. Press ON button located on the remote control transmitter

(FIGURE 1).  This will synchronize the remote control
transmitter and receiver.

 

FIGURE 1

2

5

Summary of Contents for Indoor Electric Fireplace

Page 1: ...W rite your Remote Control Code Number Here Quality checked by ...

Page 2: ...se within on year will be repaired or replaced without charge The Company will not be responsible for any expense incurred for installation removal from service or transportation costs Any such defect should be brought to the attention of the Dealer where the product was purchased and is authorized to repair or replace within the terms of this warranty The Company s only obligation under this warr...

Page 3: ...tc the mirror surface may collect dust particles these can be removed by buffing lightly with a clean dry cloth To remove fingerprints or other marks the mirror can be cleaned with a damp cloth using good quality household glass cleaner The mirror should be completely dried with a lint free cloth or paper towel CAUTION Do not use abrasive cleaners on mirror surface or spray liquids directly onto a...

Page 4: ...rer may cause fire electric shock or injury to persons 11 Do not burn wood or other materials in this fireplace 12 Do not strike fireplace glass 13 Always use a certified electrician for installation 14 Disconnect all power coming to fireplace at main service panel before performing any cleaning or maintenance 15 When transporting or storing the fireplace keep in a dry place free from excessive vi...

Page 5: ... log only apply force to the ember bed section not directly to the logs OPERATION REMOTE CONTROL The Optiflame fireplace is supplied with a radio frequency remote control all models except BF30E This remote control has a range of approximately 50ft 15 25m it does not have to be pointed at the fireplace and can pass through most obstacles including walls It is supplied with one of 243 independent f...

Page 6: ...manner to the remote control with switches located on the fireplace FIGURE3 A Main Power Switch models with remote control Main on off switch supplies power to the remote control receiving unit When placed in the on position level 1 indicator will flash Main Power Switch models without remote control Main on off switch activates the flame effect B Heater Control Switch models with remote control O...