background image

 

7

 
Electrical Connection

 

Required conductor cross section 3 x 1.5 mm².  
If a flexible power cord is used, the cord must be fed through the 
white cable entry and the cable gland supplied with the unit prior 
to installation. Firmly tighten the cable gland and secure it to the 
support (A) provided inside the unit. Strain relief is to be ensured!  
Connect phase conductor (L) and neutral conductor (N) to the 
terminal block. Pay attention to terminal markings.  
Properly connect protective earth conductor to the base plate. 
When using a flexible power cord, a suitable cable lug, e.g. eye 
lug, is required. 

Final Assembly

 

Tilt casing cover somewhat toward the front and latch top of cover on to base plate. Slide white 
cable entry into casing cover recess. Tilt casing cover toward the rear. Firmly tighten fixing 
screws inside the unit by turning them to the left (in anticlockwise direction). 

Operation

 

   When in use, the air outlet grille gets hot. Do not touch or cover! 

The hand dryer has a proximity switch which switches the dryer on automatically when hands are 
placed under the air outlet nozzle and switches off when the hands are removed from the hot 
airflow. There is a run-on delay of approximately 2 seconds. The sensitivity of the proximity 
switch can be reduced by turning the potentiometer on the electronic circuit board to the left (in 
anticlockwise direction). This must be carried out by a competent electrician. Please refer to the 
"Circuit Diagram" section overleaf for details. 
 

Cleaning 

   Allow appliance to cool before carrying out any cleaning work! Wipe the outside of the unit 

and the sensor lens (at the bottom of the air outlet nozzle) with a damp cloth and dry. Do not use 
any caustic or abrasive cleaning agents. The appliance should not be subjected to water spray. 
Hold a vacuum cleaner against the air inlet openings and/or the air outlet nozzle to remove any 
dust that may have accumulated inside the unit. 

 The hand dryer casing may only be opened by a competent electrician!  

Troubleshooting

 

Problem 

Possible cause 

Remedy 

 

Household fuse tripped. 

Check fuse. 

No stream of hot  
air 

Overheat protection tripped. 

Allow unit to cool sufficiently. 

 
 

Sensor lens of proximity switch has 
been deliberately covered (e.g. by 
chewing gum, adhesive tape, etc.). 

Remove foreign matter from sensor 
lens, clean sensor lens of proximity 
switch. 

 

Sensor lens excessively dirty 

Clean sensor lens 

 

Insufficient distance from shelf. 

Distance from shelf must be min. 
400 mm. 

Device switches 
on accidentally 

Objects with reflecting surface within 
range of sensor 

Remove objects 

 

Sensitivity of proximity switch set too 
high. 

To be carried out by a competent 
electrician: Reduce sensitivity (see 
section "Circuit Diagram"). 

A

Summary of Contents for HD 701 AM

Page 1: ...atisch ab Die Montage des H ndetrockners darf nur in einem geschlossenen Raum erfolgen Der H ndetrockner wird an einer senkrechten Wand mit der Luftaustritts ffnung nach unten montiert Die Montage und...

Page 2: ...nung nach unten zu befestigen Ma e in mm Die vier Befestigungsbohrungen 235 mm x 197 mm kennzeichnen siehe Abbildung oben Vor der weiteren Montage entsprechenden Stromkreis vom Netz trennen Sicherung...

Page 3: ...Schaltbild Reinigung Ger t nur im abgek hlten Zustand reinigen Die Ger teoberfl che und das Sensorfenster an der Unterseite der Luftaustrittsd se mit einem feuchten Lappen abwischen und abtrocknen Kei...

Page 4: ...ad bshg com F r die Auftragsbearbeitung werden die Erzeugnisnummer E Nr und das Fertigungsdatum FD des Ger tes ben tigt Diese Angaben befinden sich auf dem Typschild in dem stark umrandeten Feld Gara...

Page 5: ...y It must be mounted on a vertical wall with the air outlet opening pointing downwards The installation and electrical connection of the hand dryer may only be performed by a competent electrician All...

Page 6: ...illing template with the dimensions of the mounting plate Mount the hand dryer on a vertical wall with the air outlet opening pointing downwards bearing in mind the mounting dimensions detailed below...

Page 7: ...n be reduced by turning the potentiometer on the electronic circuit board to the left in anticlockwise direction This must be carried out by a competent electrician Please refer to the Circuit Diagram...

Page 8: ...s guaranteed for two years in accordance with our guarantee terms Disposal The appliance must not be disposed of with household waste Glen Dimplex Deutschland GmbH Phone 49 0 9221 709 564 Am Goldenen...

Reviews: