1 x Handwash Unit

1 x Swivel Arm and sprayhead

1 x Screw Pack

Specification

Power Rating: 2.7kW at 230V/3kW at 240V

Vented Open Outlet System

High Temperature cut-out: 55

O

C

+

/

3

O

C

Electricity Supply~230-240V/50Hz

SECTION 1 

Important

1) Installation must be carried out by a 

suitably qualified person and conform with 

IEE Regulations and National Water council 

bylaws.

2) This Handwash unit is designed to be 

connected to a 15mm cold water mains 

supply.

Do not connect to a tank supply.

3) All plumbing connections must be 

completed before making the electrical 

connections. 

4) The minimum recommended running 

water pressure to which the Handwash 

may be connected is 15lb/sq in (1 Bar) 

running pressure at 8 litres per minute. 

The maximum static pressure 

recommended is 150lb/sq in (10 bar).

5) The Handwash unit must not be fitted 

where it may be exposed to frost, for 

example in an outdoor area. The 

handwash must not be used if suspected 

of being frozen. Frost damage is not 

covered by the guarantee.

6) Plumbers jointing compound should not be 

used. The use of compound invalidates the

guarantee.

7) The outlet of your handwash acts as a vent 

and must NOT be connected to any form 

of tap or fitting other than that supplied 

with the unit.

8) The sprayhead must be cleaned regularly 

to remove the scale and debris. If the 

water becomes hot and you are unable to 

obtain cooler water, check the spray head 

for blockage.

9) The handyman heats water as it passes 

through the unit. Water temperature may 

therefore vary accordingly to changes in 

water flow and temperature, which may 

be affected by other water apparatus 

operated in the building and seasonal 

variations in incoming water temperature.

10) Not suitable for drinking water.

SECTION 2

Installation

Plan the Installation carefully, before starting

any part of the installation. 

Use only the rising main, do not connect the

handwash unit to the down service from a

cold water storage tank.

The water supply pipe may enter the unit

either from the bottom or the rear of the unit.

UNPACKING AND IMPORTANT NOTICES / INSTALLATION

Handyman

Dimp-13460-HandyInstruction-rob  4/22/04  5:18 PM  Page 3

All manuals and user guides at all-guides.com

Summary of Contents for Handyman

Page 1: ...K Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Tel 0870 077 7117 Fax 0870 727 0109 Email customer services glendimplex com Customer Services Tel 0870 240 9402 Dimp 13460 HandyInstruction rob 4 22 04 5 18 PM Page 1 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...e guarantee 6 Plumbers jointing compound should not be used The use of compound invalidates the guarantee 7 The outlet of your handwash acts as a vent and must NOT be connected to any form of tap or fitting other than that supplied with the unit 8 The sprayhead must be cleaned regularly to remove the scale and debris If the water becomes hot and you are unable to obtain cooler water check the spra...

Page 3: ... Connect the Neutral wire to the terminal marked N Connect the Earth wire to the terminal marked E Ensure that the terminal screws are fully tightened and good electrical continuity is achieved Secure the cable to the unit using the cable clamp Do no switch on the electricity supply to the unit SECTION 5 Final Assembly Ensuring the temperature control knob is set to MIN place the cover carefully o...

Page 4: ...a person authorised by Glen Dimplex UK Limited This guarantee is only valid within the United Kingdom This guarantee does not affect your statutory rights COOLER WARMER WARMER Handyman INSTALLATION OPERATION SECTION 8 Maintenance The sprayhead should be cleaned periodically to remove limescale and any other particles trapped in the swivel arm This may be done by unscrewing the sprayhead and scrubb...

Reviews: