EN-5
1802/A
www.dimplex.de/en
English
FPE 050E - FPE 200E
8. Operation
8.1 Switching the heating device on/off
Press the ON/OFF key. A melody sounds.
-
Display illuminates green: Heating device switched
on.
-
Display illuminates red: Heating device switched
off.
8.2 Manual operation
Press the MANUAL key once or multiple times.
The operating mode switches between:
-
Comfort temperature,
-
Eco temperature (lowered temperature)
-
Frost protection (display HD).
Setting the comfort temperature
NOTE
Temperature setting only possible if comfort
temperature is pre-selected.
Press the MANUAL key once or multiple times until
the COMFORT TEMPERATURE symbol appears.
Press the + / - keys to set the desired temperature
value.
Lowering the temperature
NOTE
Recommended for periods of absence lasting less than
24 hours to save energy.
Press the MANUAL key once or multiple times until
ECO appears.
The temperature value is lowered by 3.5°C compared
with the set comfort temperature.
Specify the frost protection temperature
NOTE
Recommended for periods of absence lasting longer
than 24 hours to save energy.
Specify a frost protection temperature of 7°C.
Press the MANUAL key once or multiple times until
HD appears.
8.3 Automatic operation
Press the AUTOMATIC OPERATION key.
Press the + / - keys to set the desired temperature
value.
The presence detection is active. The controller
detects whether a person is in the room. The set
comfort temperature remains active for as long as a
person is detected. If the room is not in use, the
temperature is lowered gradually.