Installation and Operating Instructions
Dimplex Convector Heaters
INDCUK3BQR Issue 0
Models : DY73, DY77 and DY78.
432
Wall Mtd.
Floor Mtd.
MIN
230
357
230
MIN
MIN
230
697 - 3.0kw
577 - 2.0kw
156
450
MIN
Dimensions
(millimetres)
Models Specification
DY73
2.0kw Switch/Thermostat
DY77
2.0kw 2 Neon Switches/Thermostat/Turbo
DY78
3.0kw 2 Switches/Thermostat/Neon
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
Wall Mounting
IMPORTANT SAFETY ADVICE
Three identical wall mounting brackets are secured to the base of the
heater with a fixing screw. To wall mount appliance, first remove the
brackets as follows :
WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
Lay the heater on its back. Following the sequence in Fig. 1 – identify
and remove the fixing screw securing the brackets located beside Mains
Cable as shown in (a), then pull out brackets and rotate them to
disengage them from the slot (b).
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
Withdraw the brackets from the slot (c).
FOLLOW these instructions carefully.
NEVER cover or obstruct in any way the heat outlet slots at the top
of the heater or the air inlet slots in the base of the heater.
The heater carries a warning ‘DO NOT COVER’ to alert the user to the
risk of fire that exists if the heater is accidentally covered.
If young children, the aged or infirm are likely to be left in the vicinity
of the heater, we advise that adequate precautions should be taken.-
(a)
(b)
(c)
We recommend that a guard be fitted to ensure contact with the
heater is avoided and objects cannot be inserted into the product.
Fig. 1
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
Select a suitable position on a wall, near to a mains power socket,
making sure that there is
at least
230 mm below the heater and
at least
450 mm above the heater of unobstructed space. See also ‘Positioning
the heater’.
For further information, please contact our guard supplier direct on
Tel. No. 01603 667957, or in case of difficulty or for further advice
contact the Customer Helpline.
Fix the two top retaining brackets to the wall, using suitable fixings, for
2kw models at 358 mm centres and the 3kw model at 478 mm centres –
see Fig 2.
520 mm
min.
3 No. Wall
Mounting
Brackets
floor
3kw - 478mm centres
2kw - 358mm centres
526 mm
min.
bracket
slot
shelf /
ceiling
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is fitted with
a rewirable plug incorporating a 13 amp fuse. In the event of replacing the
fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS 1362
must be used. If any other type of plug is used, a 15 amp fuse must be
fitted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug
should be removed. Before wiring the appropriate plug, please note that
the wires in this mains lead are coloured in accordance with the following
code :
GREEN AND YELLOW :
EARTH
BLUE :
NEUTRAL
BROWN :
LIVE
Fig. 2
Connect the
GREEN AND YELLOW
wire to the terminal marked ‘
E
’ or by
the earth symbol
,
or coloured
GREEN
or
GREEN AND YELLOW
.
Connect the
BROWN
wire to the terminal marked ‘
L
’ or coloured
RED
.
Connect the
BLUE
wire to the terminal marked ‘
N
’ or coloured
BLACK
.
Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.