background image

 

7

EN

A fault, what to do?

Attention!
Repairs must only be carried out by an authorised technician. Improper repairs can lead to risk of serious injury to 
the user.

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy 
the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service 
personnel.

Faults that the customer can troubleshoot himself

Fault

Cause

Solution

Water flow-rate is too low

The filter in either the water tap or the 
showerhead is clogged.

Remove the filter and either clean it or 
descale it.

A high water temperature is 
set, but it is not reached.

The continuous-flow heater is connected 
to a thermostatically-controlled water tap.

Set the temperature on the continuous-flow 
heater to „60 °C“.

The display is blank.

The fuse in the fusebox has tripped/blown.

Check the fuse in the fusebox.

The water is not warm.

The supply temperature has reduced.

Reduce the water flow on the taps until the 
desired water temperature is reached.

The temperature of the water 
leaving the tap is higher than 
the set temperature.

The temperature of the water supplying the 
continuous-flow heater is higher than the 
set temperature (e. g. due to pre-warmed 
water supplied from a solar water heater).

The thermostatic premixer in the domes-
tic supply must be set accordingly to lower 
temperatures.

“°C” flashes in the display.

The power limit has been reached.

Reduce the water flow at the tap or lower the 
temperature setting on the appliance.

If the fault could not be eliminated, please call customer service.

Faults that the customer service specialist should troubleshoot

Fault

Cause

Solution

Water flow-rate is too low 
despite cleaning of filter using 
the water tap or showerhead

A filter in the appliance is clogged.

Get a servicing expert to clean the appliance.

The display is blank despite 
fault-free function of the 
mains electricity supply fuses.

There is a fault in the appliance.

Get a servicing expert to check the appliance.

The display shows the error 
code “E..”.

There is a fault in the appliance.

Get a servicing expert to check the appliance.

Faults that are automatically remedied

Fault

Cause

Solution

The display shows “00,0°C”.

The air sensor in the appliance detects air 
in the water and momentarily switches the 
heating element off.

After a few seconds, the continuous-flow 
 heater automatically goes back into operation.

Warranty

This product is supplied with a two-year warranty according 
to our terms of guarantee. The warranty conditions in the 
country of purchase apply to this appliance. Information can 
be obtained at any time from the retailer from whom the ap-
pliance was purchased.

Summary of Contents for DES 1821

Page 1: ...ja u ytkowania Polski DES 1821 DES 2427 Elektronisch geregelter Durchlauferhitzer Electronically regulated Continuous ow heater Chauffe eau instantan r gulation lectronique Elektronisch geregelde door...

Page 2: ...t verrin gerten physischen sensorischen oder men talen F higkeiten oder Mangel an Erfahrung und Wissen benutzt werden wenn sie be aufsichtigt oder bez glich des sicheren Ge brauchs des Ger tes unterwi...

Page 3: ...aus der Leitung entwichen ist Sicherungen wieder einschalten Warmwasserhahn ganz ffnen und mindestens eine Mi nute lang Wasser beziehen Aus Sicherheitsgr nden beginnt das Ger t erst danach mit dem Hei...

Page 4: ...Auslauftemperatur ist h her als die eingestellte Temperatur Die Zulauftemperatur im Durchlauferhitzer ist h her als die eingestellte Temperatur z B durch vorgew rmtes Wasser aus der Solaranlage Der Th...

Page 5: ...ed by children aged 8 years and older as well as by per sons with diminished bodily sensory or mental perception or those who lack knowledge or experience if they are moni tored or have received instr...

Page 6: ...y forced out of the water pipe Switch the fuse back on again Open the warm water tap fully and allow water to ow for at least one minute Only then for safety reasons will the appliance begin to heat T...

Page 7: ...due to pre warmed water supplied from a solar water heater The thermostatic premixer in the domes tic supply must be set accordingly to lower temperatures C ashes in the display The power limit has b...

Page 8: ...des enfants d au moins 8 ans ainsi que par des per sonnes capacit s physiques sensorielles ou mentales r duites ou par des personnes exp riences et savoir insuf sants dans la mesure o ils sont survei...

Page 9: ...ence pas chauffer avant L appareil est pr t au fonctionnement Economies d nergie R gler la temp rature d eau souhait e directement sur l appareil Remarque le fait d ajouter de l eau froide au niveau d...

Page 10: ...la temp rature con gur e La temp rature d alimentation dans le chauffe eau est sup rieure la temp rature con gur e par ex en raison d eau pr chauff e provenant de l installation solaire Le pr m lange...

Page 11: ...n 8 en ouder en personen met beperkte fysieke zintuiglijke of verstandelijke vermogens of gebrek aan ervaring en kennis worden ge bruikt mits ze onder toezicht staan of zijn ge nstrueerd in het veilig...

Page 12: ...gen weer in De warmwaterkraan volledig openen en ten minste een minuut lang water tappen Om veiligheidsredenen begint het apparaat pas daarna met verwarmen Het apparaat is klaar voor gebruik Energiebe...

Page 13: ...zonne energiesysteem De thermostaatvoormenger in de huisinstal latie moet dienovereenkomstig op een lagere temperatuur worden ingesteld Op het scherm knippert C De vermogensgrens is bereikt De waterho...

Page 14: ...urz dzenia mog korzysta dzieci w wie ku od lat 8 oraz osoby z ograniczonymi zdolno ciami zycznymi sensorycznymi lub psychicznymi oraz bez do wiadczenia lub wiedzy je li b d nadzorowane lub zosta n za...

Page 15: ...nie zimnej i ciep ej wody w armaturze powoduje niepotrzebne zu ycie wody i energii Ponadto powoduje to wzmo one osadzanie si kamienia ko t owego w urz dzeniu Dlatego zawsze ustawia wymagan temperatur...

Page 16: ...rzep ywowego jest wy sza od ustawionej temperatury np przez dop yw podgrzanej wody z instalacji s onecznej Nale y odpowiednio ustawi mieszacz ter mostatyczny instalacji domowej na ni sz temperatur Na...

Page 17: ...17...

Page 18: ...18...

Page 19: ...der Montageanweisung enthaltene Pr fprotokoll ausgef llt innerhalb vier Wochen nach Einbau der Heizung an unten stehende Adresse zu senden Eine Garantieleistung entf llt wenn vom Endabnehmer oder ein...

Page 20: ...n Dimplex Deutschland GmbH Am Goldenen Feld 18 D 95326 Kulmbach www dimplex de Telefon 49 0 9221 709 564 Telefax 49 0 9221 709 589 E Mail 09221709589 dimplex de Technische nderungen vorbehalten 2016 D...