Other Functions
Water level protection function:
When the cooling function is first turned on, the water pump works for 50 seconds.
If low water is detected, the pump will stop working and a buzzer alarm beeps 10
times. It is also fitted with a fast water level detection function. Within 10 seconds
after powering on, press and hold the
COOLER
button to start the fast water level
detection program. After hearing two beep press the
COOLER
button and the unit
will detect the water level in 3 seconds. If there is no water, the cooling function will
be turned off and the alarm beeps 10 times. The fast water level detection function is
cancelled after pressing the shutdown button or power failure.
Uninterrupted power memory function:
When the power is restored after a power outage, the fan will start in the state
before shutting down when it is turned on again. The unit will restore to the previous
settings.
Note
: the previous function will be restored (except if in sleep mode). The
timer is not memorised either.
Auto power off function:
The unit will automatically shut down after working continuously for 15 hours. If you
want to cancel this function, press and hold the
LEFT / RIGHT SWING
button for 3
seconds, the buzzer will emit three beeps and the automatic shutdown function will
be cancelled. If you wish to restore this function, press and hold the
LEFT / RIGHT
SWING
button for 3 seconds and the automatic shutdown function will be restored.
HEPA Filter replacement prompt
The appliance will alert you when the HEPA filter needs to be replaced. After a cer-
tain amount of hours of use on the Purification/AI Purification modes, the filter re-
placement indicator will flash on the digital display. Press the Purification button for
3 seconds to turn off this display.
Screen Off function
When the unit is switched on, press the Timer button for 3 seconds if you would like
to turn off the display screen.