Dimplex DC10RC Instruction Manual Download Page 2

 

 

 

PACKAGE CONTENTS 

Portable air conditioner 

Remote control 

Batteries for remote control 

 

PARTS 

 

1. Controls 

2. Remote 

receiver 

3.  Adjustable air vent 

4.  Window kit adaptor 

5. Exhaust 

tube 

6.  Upper drain plug 

 

 

 

7. Cool 

air 

inlet 

8. Cool 

air 

filter 

 

 

 

9.  Hot air inlet 

10.  Hot air filter 

11.  Lower drain plug   

 

 

 

 

 

 

Note: Make sure drain plugs (6 and 11) are fitted before use.   

 

 

 

 

CONTROLS AND DISPLAY 

 

 

 

 

 

 

 

 

 

 

1. POWER 

 

Press the POWER button to turn the unit "ON" or "OFF". 

※ 

The portable air conditioner is fitted with a compressor delay protection circuit. This 

protects the unit from possible damage due to rapid starting and stopping of its 

compressor. Compressor operation begins 3 minutes after the unit is switched on or the 

mode is switched from dehumidify to air conditioning. 

 

2. FUNCTION   

Press this button to select cooling, heating or dehumidification. 

※ 

When the heating or dehumidification functions are used the upper drain plug (6) must be 

removed and a drain hose must be attached

.

 

3. TEMP+   

 

In cooling function, this button raises the set temperature by 1°C each 

time it is pressed to a maximum of 30°C. In heating function, this button 

raises the set temperature by 1°C each time it is pressed to a maximum 

 of  25°C. 

4. TEMP- 

 

In cooling function, this button lowers the set temperature by 1°C each 

time it is pressed, to a minimum of 17°C. In heating function, this button 

lowers the set temperature by 1°C each time it is pressed to a minimum 

 of  15°C. 

 

Extendable window kit

Water tray

3

2

Summary of Contents for DC10RC

Page 1: ...fely before the appliance is scrapped 13 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge u...

Page 2: ...peration begins 3 minutes after the unit is switched on or the mode is switched from dehumidify to air conditioning 2 FUNCTION Press this button to select cooling heating or dehumidification When the...

Page 3: ...er can be used to turn the unit on automatically after a set time delay is complete 1 With the unit OFF press the TIMER button to set the desired time delay before the unit is to start 2 Choose the fu...

Page 4: ...ore use Locating the unit Install the portable air conditioner in a flat location with adequate space to ensure the air inlets and outlets will not be blocked Keep a minimum clearance of 50cm from wal...

Page 5: ...s used excess water condensation may be produced that cannot be removed via the exhaust hose This water is captured by an internal container When this container is full the unit will stop working and...

Page 6: ...This blocks the air outlet 6 Do not place the unit where the air inlets or outlets may be blocked by curtains or furniture 7 Keep the filters clean OVERHEAT PROTECTION This unit is fitted with an ove...

Page 7: ...he temperature has decreased then turn the air conditioner on again Note Compressor operation begins 3 minutes after the unit is switched on The distance between the remote control and the air conditi...

Page 8: ...Power Consumption EN14511 1245W 1090W Rated Power EN60335 1280W 1100W Cooling Heating Capacity 3000W 3000W Air Flow 360 M3 H Moisture Removed 40 L DAY Refrigerant R410A Min room size 10m 2 Max room s...