Dimplex DAC 12005 Instruction Manual Download Page 3

2

FEATURES

The air-conditioning unit is of the mono tube type, transportable (on wheels) with air/air
operating system for domestic use and has 3 settings.

• Ventilate/Fan.

• Cool.

• Dehumidify.

The ventilation mode "moves" the air allowing for its recycling much like a fan.

The cooling mode, a refrigerating circuit (compressor), cools the room by transferring
the heat from inside to outside though the air exhaust hose.While cooling, the air-
conditioning unit also dehumidifies the room air.

Dehumidification, in the cooling mode your air-conditioner does remove moisture from
the air however another feature of this machine it can be set up to operate as a
dehumidifier with greater moisture removal performance.

SPECIFICATIONS

DAC9005

DAC12005

Cooling Capacity

9000BTU/hr

12000BTU/hr

2270Kcal/hp

3024Kcal/hp

2638 watts

3529 watts

Power  consumption

830 Watts

850 Watts

Air Volume (max setting)

470m

3

/h

520m

3

/h

Humidity removal capacity

26L/day

31L/day

Net weight

29kg

31kg

Power supply

230-240V/50Hz

230-240V/50Hz

Compressor

Rotary

Rotary

Refrigerant

R407C

R407C

Fan Speed

2

2

Timer

1-8 hours

1-8 hours

Thermostat

18-32°C

18-32°C

Dimension(WxDxH)

377x400x750 mm

430x403x753 mm

Test Conditions

Temperature 27°C

Temperature 27°C

Humidity 60%

Humidity 60%

Dimplex DAC12005_9005.qxd  7/5/05  3:34 PM  Page 2

Summary of Contents for DAC 12005

Page 1: ...Portable Air Conditioner DAC 9005 DAC 12005 Please read this manual carefully before use and keep it for future reference...

Page 2: ...a Dimplex portable air conditioner This manual contains information regulations and warnings which are of fundamental importance if the appliance is to be installed correctly and the highest performan...

Page 3: ...r air conditioner does remove moisture from the air however another feature of this machine it can be set up to operate as a dehumidifier with greater moisture removal performance SPECIFICATIONS DAC90...

Page 4: ...correct wall socket Mount the exhaust hose on the portable air conditioner The air conditioning unit should only be used by adults do not allow children to play with it ENERGY SAVING TIPS Do not cover...

Page 5: ...ully and save them in a safe place for future reference 1 Control panel 2 Cooling air outlet 3 Handle 4 Castor 5 Air filter 6 Air inlet 7 Exhaust air outlet 8 Cord hanger 9 Water stopper rubber plug i...

Page 6: ...ray 9 Drain hose ACCESSORIES 5 INSTALLATION Mounting of the unit This unit is a PORTABLE AIR CONDITIONER It can be moved from room to room so the cooling can follow you anywhere The mounting is easy b...

Page 7: ...xhaust hose can be extended from 50cm to 150cm for mounting It is recommended that you use the hose in the shortest possible length 2 Take care to prevent any bow or bend in the middle of the exhaust...

Page 8: ...ottom left side of the machine Normally an adequate quantity of water is collected to keep the recycling process operating During very humid conditions the collection of water may over take the evapor...

Page 9: ...ting the Temperature Turn the THERMOSTAT to regulate the temperature you desired This is for cooling mode only Regulating air flow direction Turn the roller on air vent to control the air flow directi...

Page 10: ...d as follows 1 Turn off the unit 2 Position the supplied plastic water tray flat on the floor under the drain hole 3 Remove the water stopper and the rubber plug Empty the condensed water from the air...

Page 11: ...is full the Full Water indicator will illuminate and the compressor will shut off automatically the fan will stay on circulating the air At this time you must empty the water tank as described in the...

Page 12: ...ters and then rinse thoroughly under running water no hotter than 40 C Dry thoroughly before replacing NOTICE Never operate the unit without the filters End of season storage Unplug the unit Drain the...

Page 13: ...es passed after switching on the unit check whether the water tray is full The room temperature should be in the operation range of 18 C 32 C Is the set temp higher than the room temp Add water as des...

Reviews: