Figure 4

.562 DIA. KNOCKOUTS

FOR CEILING MOUNT

(SEE NOTE BELOW)

FRONT PANEL

"A"

1

1.375 DIA.

"E"

"C"

1.375 - 2.000 DIA.

KNOCKOUT  SCHEDULE

.875 DIA.

1.750 - 2.000 DIA.

1.750 DIA.

CEILING MOUNTING HOLES ARE

OF HEATER.

SHOWN AS VIEWED FROM FRONT

"B"

INLET

"C"

"A"

"C"

"D"

"B"

ITEM

"A"

"B"

CONTROL SECTION

OUTLET

NOTE:

SIZE (INCHES)

1

2

2

QTY.

2

"D"

"E"

Figure 3

www.dimplex.com

2

 Operation

The CH Cabinet Heater is available with a choice of control 

options to provide flexibly of operation in various applications. 

The type of  control option is reflected in the Catalogue 

Number as the eighth digit. Please check one of the following 

options to ensure that is what has been ordered or required.

-3

:  The unit is automatically controlled by it’s own built-in 

thermostat with a range of 45 degrees F (7 C) to 90 degrees 

F (32 C). In addition to the toggle switch (“Heat & Fan”, 

“OFF” and “Fan Only”) this option has a two position toggle 

switch for High/Low Heat Selection and High/Low Blower 

Speed.  HIGH and LOW Heat give 100% for HIGH and 

approximately 50% Low heat. Correspondingly the blower 

speeds are approximately 1050 and 800 R.P.M. The Fan 

Delay is effective only on the “OFF” cycle, as the fan comes 

on at the same time the heat comes on, during the “Heat & 

Fan” cycle.

-T

:  This option incorporates a two position toggle switch as 

in option-3 above and functions the same way. In addition 

a low voltage control relay complete with an integral 

transformer is provided for connection to a remote 24 volt 

thermostat. The fan delay works the same as in “-3” above

also. 

-R:  

This option also 

uses the two position 

toggle switch as in 

the above options. 

Provision is provided 

for a line voltage 

thermostat. The fan 

delay works the same 

as in “-3” above. 

MOuNTING CLEARANCES

In order for this heater to operate properly the clearances 

shown in Figure 8 will have to be maintained. Failing to 

do so may result in a poor performance from the

 

heater.  

Dimensions are shown in inches (millimetres).  

DuCT COLLAR MOuNTING

An 18” (457 mm) section of duct work with 90 degrees bends 

may be added to the inlet and outlet of the heater with 8” 

(203 mm) clearance to combustible surfaces. Inlet and outlet 

grilles placed on the end of the must have a minium of 65% 

open area. Refer to Figure 9 for cross-sectional dimensions 

of duct. Duct collar inlet/outlets can be as per Figure 7. 

Secure the duct to the flanges provided.

!

 NOTE: 

 External static pressure exceeding 0.15”wg is not 

recommended.

WIRING INFORMATION

For service entrance refer to Figure 04 for knockout sizes 

1. 

available and their locations.

!

NOTE:  

For upflow application, control section and knock-

outs are located on lower right side of unit and for downflow 

application they will be on upper left hand side of unit.

All external wiring to the heater shall be in accordance 

2. 

to the Local and National Building codes. It is 

recommended that only qualified electrical personnel 

shall perform any service on this unit.

Refer to data plate and 

3. 

wiring diagram for correct 

voltage and amperage 

rating. These must be 

considered in the size of 

field wiring.

Figure 5

Figure 6

Figure 8

Figure 7

5.875

(149mm)

4.000

(102mm)

7.750

(198mm)

8.000

(203mm)

HEATER

TERMINAL BLOCK CONTROL PANEL

MOUNTING HOLES

4" (102mm) CENTRES

SECTION

A

A