Fireplace Installation
you are ready to install the
fireplace.
Wiring
WARNING:
To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING:
Ensure that the
On/Off Switch is set to the Off
position (refer to Operation
section) and that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installa
-
tion is complete.
1. Carefully remove the electrical
cover bracket from the back of
the fireplace by removing the
three retaining screws. (Figure 2)
2. Leaving a minimum of 3 in.
(7.6 cm) of slack, route the
power supply through a cable
clamp (not included) and the
hole in the electrical cover
bracket.
3. Remove the two covers off of
the unit at the front to access
the wire connections. (Figure 3)
For 120V Installations
Use two conductor, non-metallic
sheath cable with ground wire
(3 wires total) for the incoming
power supply.
CAUTION:
Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
• Connect the black wire (L1)
from the unit to the live wire
from the power supply.
• Connect the blue wire (N) and
For 120V Installations
GROUND
LINE
120 V Power
Supply
(Breaker Panel)
NEUTRAL
L
CONTROL PCB
THERMAL
CUTOUT
LE
D
C
O
N
TR
O
L B
O
A
R
D
LE
D
LI
G
H
TS
LE
D
LI
G
H
TS
LE
D
C
O
N
TR
O
L B
O
A
R
D
C
APAC
IT
O
R
FL
A
M
E
M
O
TO
R
H
EA
TIN
G
E
LEM
EN
T
H
EA
TIN
G
E
LEM
EN
T
B
LO
WE
R
M
O
TO
R
VOLTAGE SELECTOR SWITCH
C
OMM
240
120
L1
N
N
N
RL1
RL2
RL3
5
1
6
2
3
4
L1
2. For
No Heat
installations
leave L2 unconnected with
a wire connector on the end
1. Regular installation
attach N and L2 together
3. For installation with a
Heat Disconnect Switch
N
L2
See Options
Below
L2
N
Different Heat Control Options
N
L2
Wall On/Off Switch