General
This heater has been designed for fitting in the space behind the plinth of floor standing
kitchen units or other fitted furniture units. It is recommended that the heater is not
installed under cupboards used for storing perishable goods. It can be accommodated
in plinths with a minimum height of 150mm, and is suitable for cupboards of 1000mm
width and above.
Installation
Before undertaking installation work, ensure the electricity supply is disconnected
from any relevant fixed wiring.
The heater is more easily fitted during the installation of new furniture units, or on
existing furniture units if they can be temporarily moved from their position against
the wall. If an existing furniture unit cannot be moved, then it may be necessary to
remove the back of the unit in order to gain access to carry out the wiring installation.
Before installing the unit consider the location with respect to the following;
• The electrical supply and cable length.
• Position heater to deliver heat effectively without causing personal discomfort
from overheating while standing at work surfaces etc.
• Minimum plinth height of 150mm and minimum furniture unit width of 1000mm.
WARNING: The installation of this appliance should be carried out by a competent
electrician and be in accordance with the current IEE wiring regulations
and any local or insurance regulations.
6
Summary of Contents for BFH24E
Page 7: ...Aperture Dimensions Plan View Side View Front View 7 ...
Page 13: ...13 ...
Page 15: ...15 ...