IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

IMPORTANT SAFETY ADVICE

DO NOT COVER OR OBSTRUCT the air inlet or 
outlet grille.
ENSURE THE APPLIANCE IS EARTHED.

Do not use this product in areas where excessive 
dust exists.
Do not use this product with young children 
unattended.
This appliance is not intended for use by children 
or other persons without assistance or supervision 
if their physical, sensory or mental capabilities 
prevent them from using it safely. Children should 
be supervised to ensure that they do not play with 
the appliance. 

The product carries the Warning symbol 
indicating that it must not be covered.

Warning: In order to avoid overheating, do not cover 
the product.
This product must not be located immediately above 
or below a fi xed socket outlet or connection box.
Always disconnect supply before working on the 
product.
This appliance should only be connected to the fi xed 
wiring of the premises by means of conduit.
This product should be mounted safely to solid wall, 
fl oor or ceiling surfaces only.
If mounting the appliance horizontally it should not 
be mounted less than 1.8m from the fl oor.
This product must not be subjected to water spray 
or immersion.
Ensure the supply cables are of adequate current 
carrying capacity and are protected by a suitable 
fuse.
This appliance should not be mounted in a toilet or 
washroom.
Ensure proper manual handling procedures are 
observed at all times.
This appliance is not intended for use by  persons 
(including  children) with reduced physical, sensory 
or medical capabilities, or lack of experience or 
knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a 
person responsible for their safety.
This product is not equipped with a device to control 
the room temperature. Do not use this product in 
small rooms when they are occupied by persons 
not capable of leaving the room on their own, unless 
constant supervision is provided.
WARNING: Isolate electrical supply to ALL modular 
linked units when carrying out maintenance.

 

Architectural Air Curtains

Models : 

ARC10E, ARC15E, ARC20E, ARC10W, ARC15W, ARC20W, 

 

ARC10WLT, ARC15WLT, ARC20WLT, ARC10A, ARC15A & ARC20A

Electrical

The installation of this appliance should be carried out by a 
competent electrician and be in accordance with the current IEE 
wiring regulations. 

Fixing Positions

This appliance may be either fi xed to a ceiling - see 

Fig. 1 

or fl oor 

mounted see 

Fig. 2

 using an appropriate foot. 

A minimum distance of 500mm is required from top of the appliance 
to the ceiling (see 

Fig. 1

) and also the distance between the 

bottom of the appliance and the top of the door should be kept to 
a minimum (see ‘C’ in 

Fig. 1

).

This appliance should not be mounted less than 1.8mt. from the 
fl oor.
To open the appliance, remove the inlet grilles (‘x’ in 

Fig. 3

Remove the front panel (‘z’ in 

Fig. 3

).

Horizontal Mounting

By using the fi xing holes in the top of the air curtain, attachment 
to a ceiling over the product can be achieved using suitable M10 
threaded steel rod or similar supports of suffi cient strength - see 
‘s’ in

 Fig. 1

.

Vertical Mounting

The architectural range of air curtains can be vertically mounted 
using a suitable fl oor foot (Ref: ARCVMF).  Contact Dimplex or 
your service agent for further information.  Refer to 

Fig. 2

 for 

fi xing details.

*

 Standard Units Only

** 

See separate specifi cation sheet from Dimplex

Models

AMBIENT 

ARC10A 

n/a

 220-240V 

~1PN 

1.5  55  3.75

ARC15A 

n/a

 220-240V 

~1PN 

2.3 82.5 3.75

ARC20A 

n/a

 220-240V 

~1PN 

3.0  110  3.75

ELECTRICALLY HEATED

ARC10E 

6.0 / 12.0 

380-415V ~3PN 

18 

60 

3.75

ARC15E 

9.0 / 18.0 

380-415V ~3PN 

27 

90 

3.75

ARC20E 

12.0 / 24.0 

380-415V ~3PN 

36 

120 

3.75

WATER HEATED (at 60/40, 55/45, 45/35 °C - LPHW)**

ARC10WLT 12 220-240V 

~1PN 

1.5  65  3.75

ARC15WLT 18 220-240V 

~1PN 

2.3  95  3.75

ARC20WLT 24 220-240V 

~1PN 3  130  3.75 

WATER HEATED (at 82/71 °C - LPHW)**

  ARC10W 

17 

220-240V ~1PN 

1.5 

65 

3.75

  ARC15W 

24 

220-240V ~1PN 

2.3 

95 

3.75

  ARC20W 

34 

220-240V ~1PN 

130 

3.75  

Model

Heat

output

kW

Electrical

Supply

Electrical 

load

(per phase)

A

Weight

kg

Recom-

mended

height

m

*

Summary of Contents for ARC10A

Page 1: ...h may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Literature downloads Heating requirement calculator Visit www dimplex co uk support A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www dimplex co uk Registered No ...

Page 2: ...ds EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC ARC10E ARC15E ARC20E ARC10W ARC15W ARC20W ARC10WLT ARC15WLT ARC20WLT ARC10A ARC15A ARC20A ...

Page 3: ...a 1 2 3 4 5 500 min H L A L W H A B ARC10 E W A 1106 360 450 1060 175 ARC15 E W A 1606 360 450 1560 175 ARC20 E W A 2212 360 450 2160 175 W B C 50mm s y x z a ...

Page 4: ...7 6 9 ARC E ARC W ARC A b a 8 ...

Page 5: ...he room on their own unless constant supervision is provided WARNING Isolate electrical supply to ALL modular linked units when carrying out maintenance Architectural Air Curtains Models ARC10E ARC15E ARC20E ARC10W ARC15W ARC20W ARC10WLT ARC15WLT ARC20WLT ARC10A ARC15A ARC20A Electrical The installation of this appliance should be carried out by a competent electrician and be in accordance with th...

Page 6: ...witch Panel Installation The backing box standard double gang should be rebated into a suitable wall The box should be fitted so that the switch panel will be flush with the wall Suitable conduit should be used where applicable to carry the cable between the heater and the switch An RJ45 Patch cable with straight through connections should be used to connect the switch panel to the appliance PCB W...

Page 7: ... the heat output on water heated models 3 An electrical 3 Port Solenoid Valve can also be connected into the system Please contact your service agent using the contact details for more details Door switch control Water heated Ambient models By including a door switch in the circuit as per D in Fig 8 the air curtain will respond to door openings as follows 1 Door opening will energise the air curta...

Page 8: ... for recycling advice in your country After Sales Service Your product is guaranteed for two years from the date of purchase Within this period we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this...

Page 9: ...nts of EEC Directives 2006 95 EC and 2004 108 EC DIMPLEX MILLBROOK HOUSE GRANGE DRIVE HEDGE END SOUTHAMPTON SO30 2DF TEL 0845 600 5111 FAX 01489 773050 WEBSITE www dimplex co uk Republic of Ireland Tel 01 8424833 GDC Group Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of GDC A division of GDC Group Ltd ...

Reviews: