background image

General

The carton contains: -

• 

 

1 x AC3CN heater

• 

 

1 x Switch box

This Recessed Ceiling Heater / Over Door Heater is a robust heater intended 
for installation into a suspended or plasterboard ceiling.
For optimum results, do not  install this product in ceilings higher than 3 metres. 
If multiple heaters are installed, generous spacing should be provided between 
heaters to achieve an even heating distribution.

Electrical Connection

The Electrical connection of this product should be carried out by a competent 
electrician and be in accordance with the current IEE wiring regulations. 
A suitable local isolating switch must be provided in the electrical supply circuit 
with at least 3mm clearance on each pole. 

Connection of Heater

Gain access to the terminal block (see ‘x’ in 

Fig. 2

) by unlocking the grill by 

moving the two slides in the direction of the arrows (see ’A’ in 

Fig. 2

) as shown 

using  a  small  screwdriver  or  other  suitable  tool.  Open  the  grill  and  feed  the 
appropriate cable through the cable gland (see ‘Y’ in Fig. 2).  

WARNING: 

Ensure power cable path does not come into contact with internal 

heater elements or fans.
Make connections as per wiring Diagram (see 

Fig. 3

) and close the grille.

Connection of Switch Panel

The  mains  electrical  supply  cable  and  power  cable  to  this  heater  (neither 
supplied)  should  be  connected  as  per  the  wiring  diagram  shown  in 

Fig. 4 

(see 

Fig. 5

 for Switch No.’s).

Label 

Description

1

       

ON - OFF (Double Pole Switch)

2

       

HALF HEAT (Single Pole Switch)

3

       

SECOND HALF HEAT (Single Pole Switch)

      

TERMINAL BLOCK

M       

MAINS IN POWER CABLE (NOT SUPPLIED)

B

        

BLOWER MOTOR

E        

HEATER ELEMENT

T

        

TERMINAL BLOCK

C

        

POWER CABLE FROM SWITCH PANEL TO

             HEATER (5 core - NOT SUPPLIED)

I

          Isolators

  Test  all  switch  settings  once  installation  is 

complete 

Installation of Switch Panel

X

Y

A

Fig. 2

Fig. 1

Recessed  Ceiling Heater / Over Door Heater
Model: AC3CN

Model 

Loading 

 Current 

Voltage 

Weight 

 

  (kW) 

(amps) 

(volts) 

(kg)

AC3CN 

13 

 230-240 

8.7

579

271

209

639

330

105

48

500

H1 

H2 

N

Fig. 3

Fig. 4

M

I

I

Summary of Contents for AC3CN

Page 1: ...eater The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC 0 250 SCALE ...

Page 2: ...less continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not pl...

Page 3: ... any flammable materials or sprays in the vicinity of the heater FIRE HAZARD DO NOT insert any foreign objects into the heater openings Risk of injury electric shock or damage to the heater may occur Ensure proper manual handling procedures are observed at all times ATTENTION IN ORDER TO AVOID OVERHEATING DO NOT COVER ...

Page 4: ... screwdriver or other suitable tool Open the grill and feed the appropriate cable through the cable gland see Y in Fig 2 WARNING Ensure power cable path does not come into contact with internal heater elements or fans Make connections as per wiring Diagram see Fig 3 and close the grille Connection of Switch Panel The mains electrical supply cable and power cable to this heater neither supplied sho...

Page 5: ...d into the M8 threaded inserts located in the top side of the heater see Fig 1 for dimensions Adjust the height of the heater so the inner edge of the grill surround is flush with the ceiling Installation in a Bulk Head over doorway A hole 579x271mm as indicated in Fig 7 must be cut into the ceiling part of the bulk head Drop rods should be used to mount the appliance in such a position as to have ...

Page 6: ...ed off and an engineer called Maintenance WARNING ALWAYS DISCONNECT HEATER FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE The heater should be serviced annually Any dust or debris should be removed from the grille and elements taking care not to damage the elements Cleaning the Heater Switch Panel External and grille appearance can be maintained by occasionally vacuuming and wiping with a...

Page 7: ......

Page 8: ... 879 3587 FAX 0844 879 3582 WEBSITE www dimplex co uk Republic of Ireland Tel 01 8424833 GDC Group Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Dimplex A division of GDC Group Ltd ...

Reviews: