![Dimplex 6901470100 Practical User'S Manual Download Page 8](http://html1.mh-extra.com/html/dimplex/6901470100/6901470100_practical-users-manual_2504601008.webp)
Warning:
Allow at least 10 minutes for the light bulbs and heater to cool before
attempting any maintenance or cleaning.
Bulb Requirements
Quantity 2 clear chandelier or candelabra bulbs with an E-12 (small) socket
base, 60 watt rating. Example: GE 60BC or Philips 60CTC
Tools required:
Philips screwdriver
1. Remove the fireplace trim.
2. With a Philips screwdriver remove the two outer screws from the log
grate.
3. Slide the light assembly out of the insert by pulling the log grate
until the light assembly reaches the stop (approximately 2”)
4. Remove the log set by lifting straight up.
5. Examine the bulb(s) to determine which bulb(s) require replacement.
6. Unscrew the bulbs counter clockwise.
7. Insert new bulbs.
8. Replace the log set into the insert.
9. Slide the light assembly back into the insert.
10. Install the two outer screws into the log grate.
11. Reinstall the fireplace trim.
5