Press + to select more weekdays.

• 

The selected weekdays are marked with a triangle displayed 

permanently. The days Monday to Friday are selected on the screen 

at the top. Deselect weekdays with the - key.

• 

Press the ENTER key. The settings are saved. COPY flashes three 

times. Setting is complete.

Frost Protection

In MANUAL OFF operating mode and Auto operating mode (time block 

OFF), frost protection takes place. If the room temperature is 5° C or 

less, the heating device is switched on automatically.

Adaptive Start

This function guarantees that, in automatic mode (week program), the 

set room temperature is achieved exactly at the start of the switch-

on time.

Example:

In the timer menu, a set room temperature of 22°C is specified. The 

current room temperature is 17° C. The heating device switches on early 

so that the specified room temperature of 22° C is reached by 07:00.

• 

Use the MODE key to select the operating mode AUTO

• 

Press and hold the + and - keys for three seconds

• 

ECO appears

• 

Activate / deactivate the function with the +/- keys:

• 

ON = Adaptive start activated

• 

OFF = Adaptive start deactivated

• 

Press the ENTER key. Setting is saved. 

Options

Key Lock

This function can be used to lock the operating elements

• 

Press and hold the ENTER key and MODE key for one second

• 

The LOCKED key symbol appears in the display.

• 

To unlock, press and hold the ENTER key and the MODE key at 

the same time again

NOTE:  No settings can be made if the key lock is activated

Use the +/- keys to set the weekday

Setting time block ON

• 

press the ENTER key. P1 (period 1) and ON apprears. The hours 

display flashes

• 

Use the +/- keys to set the hours. Press the ENTER key. The 

minutes display flahses.

• 

Use the +/- to set minutes (in 10 minute increments)

Setting time block OFF

• 

Press the ENTER key. P1 (program 1) and OFF appears. The hours 

display flashes.

• 

Use the +/- keys to set the hours. Press the ENTER key. The 

minutes display flashes.

• 

Use the +/- keys to set the minutes

Temperature setting

• 

Press the ENTER key. Temperature setting appears

• 

Use the +/- keys to set the temperature.

• 

Press the ENTER key. P2 (program 2) and ON appears. The hours 

display flashes.

The programs P2, P3 and P4 can be set in the same way. 

NOTE:  To exit the program early, press the PROG key

Copying Programs

To copy the newly set programs P1 - P4 to other days, proceed as follows.

• 

After carrying out the Temperature Setting, press and hold the 

ENTER key until COPY appears.

Turbo Fan

The turbo fan can be used to circulate the heat around the room to 

help it reach the desired temperature more quickly. On this model with 

the ON/OFF switch at ON position and the turbo switch in the OFF 

position, there will be 2kW output from the convector (NOTE: 2kW is 

only possible with turbo OFF). To activate 3kW output, turn ON the 

turbo switch which will combine the 2kW setting with a 1kW fan boost 

setting to give a total of 3kW with fan boost. 

Recycling

For electrical products sold within the European Community. At the end of the electrical products useful life it should not be 

disposed of with household waste. Please recycle where facilities exist. Check with a Local Authority or retailer for recycling advice 

in your country. Batteries should be disposed of or recycled in accordance with WEEE Directive 2012/19/EU. Packaging should 

be recycled where possible.

Summary of Contents for 403TSFTIE7

Page 1: ... 2 Series A Convector Heaters Model 403TSFTIE7 These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MANUAL Installation and Operating ...

Page 2: ...heater must be on a flat stable surface when in use If the radiator is tipped over unplug it and allow it to cool before standing it back up DO NOT pull the radiator along by the mains lead The supply cord should be uncoiled before use IMPORTANT SAFETY ADVICE WARNING To avoid danger of suffocation please remove all packaging materials particularly plastic and EPS and keep these away from vulnerabl...

Page 3: ...itted in the plug the adaptor or at the distribution board IMPORTANT If the plug is not suitable for your socket the 13 amp plug should be removed Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE Connect the GREEN AND YELLOW wire to the terminal marked E or by the earth...

Page 4: ...ove the heater of unobstructed space See also Positioning the hetaer Fix the two top retaining brackets to the wall using suitable fixings 3kW models at 478mm centres see Fig 2 b Fig 1 Wall Mounting Brackets Positioning the Heater WARNING DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS ARE FITTED CORRECTLY The product can be used as an installed or portable unit Once the desired application ...

Page 5: ...blocks are specified at the factory These must be defined by the user as required NOTE In time block OFF frost protection is set at the factory If the room temperature is 5C or less the heating device is switched on automatically MODE Automatic mode week program Manual operation ON Manual operation OFF ENTER Save entry PROG Week program set clock KEYS Used to navigate through the menu and to chang...

Page 6: ...nd ON apprears The hours display flashes Use the keys to set the hours Press the ENTER key The minutes display flahses Use the to set minutes in 10 minute increments Setting time block OFF Press the ENTER key P1 program 1 and OFF appears The hours display flashes Use the keys to set the hours Press the ENTER key The minutes display flashes Use the keys to set the minutes Temperature setting Press ...

Page 7: ... use of your Dimplex product for anything other than normal domestic household purposes in the country where it was purchased Caused by any misuse abuse or negligent use of the Dimplex product including but not limited to any failure to use it in accordance with the Operating Instructions supplied with the product Caused by any failure to assemble install clean and maintain your Dimplex product in...

Page 8: ...ghts reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex This product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC ...

Reviews: