26370400_V_1_0.DOC
9/10
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, etc.
OVERVIEW
OPERATION
Install the device on a plane surface.
The device has no ON/OFF switch. As soon as you insert the jack into the IN socket, it beginns
running. Remove the jack from the IN socket when the device is not in use. This extends the life of the
battery.
Operation via the optional power-unit
Connect the connection cable of the power-unit with the DC IN-socket. Plug the power unit into your outlet.
Inserting/Replacing the battery
Please refer to the explanations under Operating Determinations.
Loosen the screws on the underside of the device and remove the base.
Insert the new battery and make sure that the poles are correct.
Replace the battery cover and close it.
1. 9 V Input Socket
Plug in your AC adapter here.
2. Power Indicator
Indicates ON/OFF and battery power.
3. Level Control
Turn clockwise to increase, turn counterclockwise
to decrease output level.
4. Feedback Control
Turn clockwise to increase, turn counterclockwise
to decrease amount of signal repetitions.
5. Delay Time Control
Turn clockwise to increase, turn counterclockwise
to decrease delay time.
6. Mode Control
A.S. 50ms: 12.5 - 50 ms delay time.
B.m. 200ms: 50 ms - 200 ms delay time.
C.L. 1000ms: 200 ms - 1000 ms delay time.
D.Hold: constant repetition of dalay signal.
7. Input Socket
Plug in your instruments, effect unit, etc here.
8. Output Socket
Plug in your amplifier here.
9. Footswitch
Turns the effect ON/OFF.