Digoo DG-TH8805 Operating Instructions Download Page 3

In normal time mode, press 

HISTORY

 to trace the barometric pressure data of the past 12 hours.

In normal time mode, press and hold 

HISTORY

 to set altitude height→weather status→air pressure unit 

→ exit. Press           or     to set desired values.

The default value is 1012hpa/70M. Air pressure unit is either hPa or inHg.

The sequence of weather status setting is partly-cloudy, cloudy, rainy, stormy and sunny.

In normal time mode, press            to check alert temperature value; press and hold          to enter alert 

setting, the digits begin flashing. 

Press 

MODE

 to set items. The sequence is ON/OFF→temperature upper limit→lower limit→exit.

Default temperature upper limit is +70 

/lower limit is -50

/the alert function defaults to be OFF.

When outdoor temperature reaches the preset alert value, it will start sounding; the temperature and 

alert icon      flash simultaneously.

Press any button will stop the alert, but the temperature and alert icon will still flash.

When the temperature returns to the range within two limits, the alert stops. Users could set the

temperature alert function to be off to stop the function.

TEMPERATURE AND HUMIDITY

Press 

CH

 button on main unit to change channel display.

The channel switch order is CH1 --> CH2--> CH3 -->Channel scan (from CH1 to CH2 to CH3, 10 

seconds intervals).

Press and hold 

CH

 button more than 3 seconds, then manually enter into RF re-registration.

Remarks:

1. The distance of main unit or transmitter should be at least 5~6.5 feet (1.5~2 meters) away from any

    interfering sources such as computer monitors or TV sets.

2. The main unit cannot stand close to metal window frames.

3. Please do not use other electrical products such as headphones or speakers operating at the same signal 

    frequency, which may cause interference.

4. Neighbors using electrical devices operating on the same signal frequency can also cause interference.

1. Indoor temperature range: 0

~+50

℃(

+32

~+122

℉)

2. Outdoor temperature range: -20

~+50

℃(

-4

~+122

℉)

    Remarks: LL.L or HH.H will display when out of the above range

3. Indoor and outdoor humidity range: 20%~95%

    Remarks: 20% or 95% will display when out of range

4. Press 

MEM

 to check maximum and minimum data

Weather forecast will appear in one of following combinations:

Real time weather forecast is based on the change of air pressure. Therefore the weather icon changes

according to the alteration of air pressure value: if the air pressure changes by +/- 2 hpa, when it goes 

up the unit displays sunny; it turns to rainy while it goes down.

The following four days’ forecast are based on change of present trend.

Remarks: 

1. When temperature is lower than 3.9

 and it rains, then the forecast would change to Snowy status.

2. Freezing point indicator will appear when RF temperature is lower than 3.9

.

OUTDOOR TEMPERATURE ALERT SETTING

BAROMETRIC PRESSURE AND WEAHTER SETTING

WEATHER FORECAST

Sunny

Partly cloudy

Cloudy

Rainy

Stormy

Snowy

Freezing Point Icon

Summary of Contents for DG-TH8805

Page 1: ...Operating Instructions 5 Day Weather Station with Color Screen Model DG TH8805 INDOOR UNIT ...

Page 2: ...in 7 languages English German French Italian Spanish Dutch and Danish Real time moonphase Low power indicator USB cable for perpetual backlight 3 AA back up batteries for memorizing time when cutting off DC power OUTDOOR SENSOR FEATURES GETTING POWERED RF Outdoor Temperature and Humidity Open the battery compartment cover Insert 3 x AA back up batteries to main unit or connect it with USB cable an...

Page 3: ... into RF re registration Remarks 1 The distance of main unit or transmitter should be at least 5 6 5 feet 1 5 2 meters away from any interfering sources such as computer monitors or TV sets 2 The main unit cannot stand close to metal window frames 3 Please do not use other electrical products such as headphones or speakers operating at the same signal frequency which may cause interference 4 Neigh...

Page 4: ...rm or quit snooze In normal time mode press and hold MODE button for 3 seconds the digits begin to flash Press or to set the clock by sequence to the desired year month date weekday language 12 or 24 hour hour minute exit Press or for advancing backwarding by one step per second press and hold or for fast advancing backwarding by eight steps per second Press MODE to confirm present item and procee...

Page 5: ...xtreme force shock or fluctuations in temperature or humidity 4 Do not tamper with the internal components 5 Do not mix new and old batteries or batteries of different types 6 Do not mix alkaline standard or rechargeable batteries with this product 7 Remove the batteries if storing this product for a long period of time 8 Do not dispose of this product as unsorted municipal waste Collection of suc...

Reviews: