Digoo DG-TH3330 Quick Start Manual Download Page 2

 

 

 

 

3.  Using other electrical products such as headphones or speakers operating on the same 

frequency 

(433MHz)

 may prevent correct signal transmission and reception.

4.  Neighbours using electrical devices operating on the 

433MHz

 signal frequency can also 

cause interference.

5.  Signals from other household devices, such as door bells and home security systems, 

may temporarily interfere with the units and cause reception failure. The transmission and 
reception of temperature reading will resume once the interference has stopped.

The maximum transmission range is 50 metres (164 feet) from the remote sensor to the monitor 
(in open space). However, this depends on the surrounding environment and interference levels. 
The temperature signal travels in a straight line from the remote sensor to the monitor. The signal 
will not curve around an object. If no reception is possible despite the observation of these 
factors, all units will have to be reset.

3.0 Mounting

CAUTION

: Great care must be taken when mounting the components. The manufacturer/ 

supplier cannot be held liable for personal or property damage when setting up the 
components. Please use caution when choosing a mounting point.

Prior to drilling mounting holes and permanently 

 any of the units, please ensure the 

following points are considered:

1. Signal from the remote sensor can be received by the monitor at mounting point.
2. Make sure the remote sensor is easily accessible. You will have to periodically replace batteries.

3.1 Monitor

The monitor can be placed on any 

 surface.

3.2 Optimum Viewing Angle

You must always keep in mind that the LCD screen is constructed with an “optimum viewing 
angle”. Your eye should be at a 45° angle to view the LCD screen clearly.

45°

3.3 Installing the Remote Sensor

To prevent temperature interference, place the remote sensor away from direct sunlight, air 
conditioning, and heater vents. The remote sensor is designed to be splash proof; never immerse 
into water or expose to heavy rain.

NOTE

: The temperature signal travels in a straight line from the remote sensor to the monitor. 

The signal will not curve around an object. Please take this into consideration when mounting the 
remote sensor.

The remote sensor can be placed on any 

 surface or mounted on a wall.

Wall Mount

4.0 Calendar and Clock Setup

1.  Press the 

SET

 button. The year digit will begin to 

2.  Press the 

UP

 or 

DOWN

 button to toggle to the correct year.

3.  Press the 

SET

 button to 

4.  The month digit will begin to 

 Follow steps 2 and 3 to set the correct month, date, hour, 

minutes and 12/24 hour format.

5.0 Setting Alarm Time

1.   Press the

 ALARM

 button once to enter alarm mode. 

 will be displayed between the hour 

and minute digits.

2.   Press the 

ALARM

 button again to activate or deactivate the alarm. When the alarm is 

activated   will be displayed between the hour and minute digits. 

3.   Press and hold the 

ALARM

 button. The hour digit will begin to 

4.   Press the 

UP

 or 

DOWN 

button to set the hour.

5.   Press the 

ALARM

 button to 

 The minute digits will begin to 

6.   Press the 

UP

 or 

DOWN

 button to set the minutes.

7.   Press the 

ALARM

 button to 

 The clock will automatically return to regular mode.

8.   When the alarm sounds press the 

SZN/LIGHT

 button, the alarm will sound again in 

approximately 5 minutes. To turn off the alarm 

 press any other button, when  

alarm sounds.

6.0 Maximum and Minimum Memory

1.   Press the 

UP/MEM 

button once to display the maximum readings. Press the  

UP/MEM

 button again to display the minimum readings.

2.   To clear the memory, press and hold the 

UP/MEM

 button when the max or min readings are 

displayed. This will reset the memory to the current temperature and humidity readings being 
displayed on the monitor.

NOTE

: All the maximum and minimum readings will be reset automatically at 12:00am (0:00) everyday.

7.0 °C/°F Switchable

The default measurement for temperature is °C, press the 

DOWN/CF

 button to toggle between 

°C and °F. 

8.0 Backlight

Press the 

SNZ/LIGHT

 button to turn the blue backlight on for a few seconds.

9.0 Product Specifications

Temperature Measuring Range

Monitor

0°C to 50°C with 0.1°C resolution
32°F to 122°F with 0.2°F resolution

When temperature is above 50°C (122°F) monitor will display HI
When temperature is below 0°C (32°F) monitor will display LO

Remote Sensor

-40°C to 70°C with 0.1°C resolution
-40°F to 158°F with 0.2°F resolution

When temperature is above 70°C (158°F) monitor will display HI
When temperature is below -40°C (-40°F) monitor will display LO

Accuracy

+/- 2°C (+/- 4°F)

Humidity Measuring Range

Monitor

20% - 95% RH

Remote Sensors

20% - 95% RH

Accuracy

+/- 5% RH (at 25°C/77°F, between 30% RH and 80% RH)
+/- 8% RH (at 25°C/77°F, between 20% RH and 29% RH, 80% RH 
and 95% RH)

Temperature & Humidity Checking Interval

Monitor

1 minute

Remote Sensor

1 minute

Power Source

Monitor

2 x AAA batteries, 1.5V

Remote Sensors

6 x AA batteries, 1.5V (using lithium batteries during the cold months 
is recommended)

Reviews: