THE DIGIVAC COMPANY (“DIGIVAC”) offers all of its products with the following terms and co

nditions and notices as follows.  

By accepting and/or using a DIGIVAC product, you hereby acknowledge and agree to the following terms and conditions, and 
acceptance  of  these  terms  and  conditions  are  a  condition  precedent  to  any  purchase/sale  agreement  between  you  and 
DIGIVAC. 
  
Exclusive Obligation:  The DIGIVAC product you are purchasing has been designed for a specific use within a set of suitable 
operating conditions, as set forth in its User Manual, or as indicated otherwise by DIGIVAC.  Any use of the DIGIVAC Product 
for any purpose or under any conditions, other than those specified, shall render any limited warranty void, and shall expressly 
invalidate  any  liability  of  DIGIVAC  for  damages  as  a  result  of  such  misuse.    User  limitation:  You  may  not  modify,  copy, 
distribute, transmit, display, perform, reproduce, publish, license, create derivative works from, transfer, or sell, any information, 
software, products or services obtained from or created by DIGIVAC to any third party, without the express written consent of 
DIGIVAC to do otherwise.  Any violation of this provision shall give rise to an indemnification of DIGIVAC by you, for any third 
party claims arising out of such violation.  THIRTY (30) DAY LIMITED Warranty: All DIGIVAC products are warranted against any 
manufactured defect for a period of thirty (30) days from date of purchase, unless such product is a custom-work for you and 
not a standard DIGIVAC product.  Any product qualifying as a custom-work shall not be warranted against any defects for any 
purpose,  and  your  acceptance  of  such  custom-work  shall  relieve  DIGIVAC  of  any  liability  for  any  purpose.    WITH  THE 
EXCEPTION OF THE LIMITED WARRRANTY ABOVE, YOU AGREE ANY DIGIVAC PRODUCT IS PROVIDED AS IS, EXCLUSIVE OF 
ANY  WARRANTY,  INCLUDING,  WITHOUT  LIMITATION,  ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY,  FITNESS  FOR  A 
PARTICULAR PURPOSE, NON-INFRINGEMENT, OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED.  Limitation Of Liability: 
You  agree  and  acknowledge,  DIGIVAC  shall  have  no  liability  to  you  whatsoever  for  any  direct,  indirect,  punitive,  incidental, 
special  consequential  damages  arising  out  of  or connected  with  the  use  or  misuse  of  its  products.   In  particular, given the 
nature of DIGIVAC products, you agree and acknowledge, under no circumstances whatsoever shall DIGIVAC be liable to you 
for any consequential damages for damage to any non-DIGIVAC product or service, arising from the failure, use or misuse of a 
DIGIVAC product, including, but not limited to, any vacuum system, engine, vehicle, factory, or the like.   In the event, a court 

of law with proper jurisdiction finds DIGIVAC liable to you for any purpose, you agree and acknowledge DIGIVAC’s maximum 

liability shall not exceed the purchase price of one unit of product giving rise to such liability, or $250.00, whichever is greater.  
Entire Obligation: These terms and conditions express the entire obligation of DIGIVAC with respect to its products.  If any part 
of these terms and conditions are deemed void, invalid, unenforceable or illegal, including, but not limited to, the warranty 
disclaimers,  liability  disclaimers  and  liability  limitations  set  forth  above,  then  the  unenforceable  clause  or  sentence  may  be 
disregarded with the remainder of these terms and conditions valid and enforced.  In the event the unenforceable clause or 
sentence leaves a void in these terms and conditions, a provision closely matching the intent of the unenforceable provision 
should  be  deemed  inherent  within  these  terms  and  conditions,  slightly  modified  to  render  such  provision  valid  and 
enforceable.    General:  These  terms  and  conditions  are  governed  by  the  laws  of  the  State  of  New  Jersey,  USA.  You  hereby 
consent to the exclusive jurisdiction and venue of the Courts of New Jersey, in all disputes arising out of or relating to the use 
of this product.  Use of this product is unauthorized in any jurisdiction that does not give effect to all provisions of these terms 
and conditions.  Modification of Terms and Conditions: DIGIVAC reserves the right to change the terms, conditions, and notices 
under which their products are offered. 

Summary of Contents for Bullseye Precision Gauge Pirani

Page 1: ......

Page 2: ...1 0 5 B C h u r c h S t M a t a w a n N J 0 7 7 4 7 7 3 2 7 6 5 0 9 0 0 s a l e s d i g i v a c c o m w w w d i g i v a c c o m Copyright 2015 DigiVac Inc All rights reserved ...

Page 3: ...utes to 2 hours Rugged design for field use Dimensions 6 2 x 3 7 x 1 3 Only requires 4 AA or Micro B USB Range of 1 millitorr to 50 Torr Accuracy from 50 millitorr 30 Torr 7 Calibration points of 5mt 50mt 1T and 30T Sensor resolution of 2 5mt display resolution of 0 1mt Number of Units 12 microns millitorr Torr mbar Bar kPa pascals PSIA mmHg inHg mmH2O inH2O Scientific notation or decimal display ...

Page 4: ...rger Quick Start guide or this user manual Remove protective boot Install batteries or attach a Micro B USB press the POWER button and verify that the display lights up Plumb Pirani vacuum sensor into the system to be measured taking care to differentiate between the threaded end and the end connecting the sensor to the cable Thread sensor cable into sensor cable connector is keyed Power on the de...

Page 5: ...5 1 0 5 B C h u r c h S t M a t a w a n N J 0 7 7 4 7 7 3 2 7 6 5 0 9 0 0 s a l e s d i g i v a c c o m w w w d i g i v a c c o m Copyright 2015 DigiVac Inc All rights reserved ...

Page 6: ...measure the heat loss of the chip resistor which is an indirect indication of pressure Most DigiVac instruments incorporate a more traditional thermocouple sensor using heated dissimilar conductors that make contact and create a temperature differential which in turn produces a voltage later translated into a vacuum reading Inexpensive Largely interchangeable Measures a wide range of vacuum Suscep...

Page 7: ... Low Resolution High Resolution and Scientific Notation Display modes are selected from the display menu Display and numeric formats are selected from the Setting option Display The SEL button enters and traverses the Settings menu The numeric display shows the currently configured units In these examples the vacuum pressure units are microns or torr In any display mode the UP and DOWN buttons tur...

Page 8: ...wn data In this mode the pump down graph is shown with a linear pressure scale that is fit to the pressure range of the data set The height of the graph display is the pressure range of the data set in a linear scale not log The top left figure is the maximum value in this range and the bottom left figure is the minimum value in this range Sometimes this visualization is not useful showing noise T...

Page 9: ...but may result in a noisier reading Low Resolution The Low Resolution format has two digits of precision For example an internal vacuum value of 1234 microns μm Hg would be displayed as 1 2 torr in the Low Resolution numeric format with torr units This number format also gives a filtered number depending on the accuracy of the gauge in the pressure range of measurement which results in a quieter g...

Page 10: ... Resolution format Large number display with the scientific format The numeric display shows the currently configured units in these examples the vacuum pressure units are microns or torr In any display mode the UP and DOWN buttons turn the backlight on and off respectively the SEL button enters the configuration menu and the ENT button turns the gauge on or off The battery indicator shown at full...

Page 11: ...hanges based on the current level of pressure The numeric display shows when the vacuum sensor is disconnected failed or when an over range condition exists pressure above 50 Torr The numeric display shows OVERRANGE when the vacuum sensor tube is disconnected failed or when an over range condition exists pressure above 50 Torr The bar graph visualizes the current sensor reading with a 6 stage step...

Page 12: ...display is the pressure range of the data set in a linear scale not log The top left figure is the maximum value in this range and the bottom left figure is the minimum value in this range The top right figure is the current or most recent value in the instrument Sometimes this visualization is not useful showing noise This noise comes from the instrument s process of measurement as well as the va...

Page 13: ...ith cleaning If the contaminant is known the sensor should be filled with a fluid that is known to be a solvent to that contaminant As an example ether is often effective in removing residues of some oils Commercial carburetor cleaners are very powerful solvents and are highly effective against some contaminants After cleaning with solvents the gauge tube should be completely dried or flushed with...

Page 14: ... Your vacuum instrument should give you many years of trouble free service There are no regularly scheduled maintenance intervals If consistent accuracy is required it is recommended that the gauge tube cable and power supply be returned for a yearly calibration check The instrument is calibrated in nitrogen which has thermal properties virtually identical to air Other gasses will affect the readi...

Page 15: ...ontroller s analog to digital converter and is a useful diagnostic The calibration points are 30 Torr the Atmospheric pressure calibration number 1 Torr Mid The middle calibration number This number literally represents the calibration curve pivot point between the high and low variables 50mT Vac The vacuum or low pressure calibration number 5mT The lowest pressure calibration number These numbers...

Page 16: ...ize the vacuum system to exactly 30 Torr then press the up and down buttons simultaneously so the unit reads exactly 30 Torr or 30000 0 Press the SEL button once more so the screen reads Press up down to Store then press up and down button simultaneously Screen will flash black and calibration offsets will be saved Pump manifold down to 1 micron and check unit reading at different points while slo...

Page 17: ...st This is done by pressing the arrow button and observing the ATM MID and VAC will be capitalized when selected Press up and down buttons simultaneously to zero out the offsets Pump manifold down to 1 micron and check unit reading at different points while slowly decreasing pressure to ensure successful calibration At pressures above 50 Torr the unit may display the text Overrange this is typical...

Page 18: ...s pressure lower than atmospheric or suction but in describing negative pressure the atmosphere is only a satisfactory reference if we are dealing with values of vacuum down to about 27 inches of mercury Below that it is much more useful to talk in terms of absolute pressure starting from absolute zero The Bullseye Pirani and all similar instruments do just this One Torr a commonly used unit is an...

Page 19: ...19 1 0 5 B C h u r c h S t M a t a w a n N J 0 7 7 4 7 7 3 2 7 6 5 0 9 0 0 s a l e s d i g i v a c c o m w w w d i g i v a c c o m Copyright 2015 DigiVac Inc All rights reserved ...

Page 20: ...20 1 0 5 B C h u r c h S t M a t a w a n N J 0 7 7 4 7 7 3 2 7 6 5 0 9 0 0 s a l e s d i g i v a c c o m w w w d i g i v a c c o m Copyright 2015 DigiVac Inc All rights reserved ...

Page 21: ...on Torr Inches of Hg kPa Inches of H20 millitorr mbar Pa PSIA mm of Hg bar and mm of H2O Calibrated under actual vacuum against a NIST standard Patent Pending vacuum graphing displays vacuum and time data Visual graphing right on the display that identifies current system status Vacuum Analytics to quickly identify vacuum pressure trends Graphical display for quick determination of vacuum level Li...

Page 22: ...HANTABILITY FITNESS FOR A PARTICULAR PURPOSE NON INFRINGEMENT OR ANY OTHER WARRANTY EXPRESSED OR IMPLIED Limitation Of Liability You agree and acknowledge DIGIVAC shall have no liability to you whatsoever for any direct indirect punitive incidental special consequential damages arising out of or connected with the use or misuse of its products In particular given the nature of DIGIVAC products you...

Reviews: