Chapter 3: Configuration
Coding:
T1 coding can be AMI or B8ZS. E1 coding can be AMI or HDB3. E1
can also have the extra flag CRC4 at the end for CRC4 checking.
Yellow:
The optional yellow flag can be added at the end for transmitting a
yellow alarm when no channels are open.
The following is a typical setup for a telco in the US:
span => 1,1,0,esf,b8zs
In Europe:
span => 1,1,0,ccs,hdb3
4.
Specify the channel definitions. The format is:
<device> = <channel list>
A list of valid devices are specified in the sample system.conf file.
The following is a typical setup for a T1 PRI in the US:
bchan = 1-23
dchan = 24
5.
DAHDI uses modular echo cancellers that are configured per channel.
The echo cancellers are compiled and installed as part of the dahdi
linux package. You can specify the echo canceller to be used for each
channel. The default behavior is for there to be no echo canceller on
Digium, Inc.