Troubles shooting
Verify that is using the right power cord/adapter (DC 48V), please don’t use the
power adapter with DC output voltage higher than 48V, or it will burn this converter
down.
Select the proper UTP cable to construct user network. Please check that is using
the right cable. Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP)
cable for RJ-45 connections: 100
Ω
Category 3, 4 or 5 cable for 10Mbps connections,
100
Ω
Category 5 cable for 100Mbps connections or 100
Ω
Category 5e/above cable
for 1000Mbps. Also be sure that the length of any twisted-pair connection does not
exceed 100 meters (328 feet).
Diagnosing LED Indicators:
the Switch can be easily monitored through panel
indicators, which describes common problems user may encounter and where user
can find possible solutions, to assist in identifying problems.
If the power indicator does not light on when the power cord is plugged in, user may
have a problem with power cord. Then check for loose power connections, power
losses or surges at power outlet. If you still cannot resolve the problem, contact the
local dealer for assistance.
If the Industrial switch LED indicators are normal and the connected cables are
correct but the packets still cannot transmit. Please check your system’s Ethernet
devices’ configuration or status.