16
8.5.
Abnormally stop charging
1.
Forced fault stop: A fault stop initiated by the onboard
charger of vehicle.
2.
Automatic fault stop: A fault stop initiated by the
charging station due to internal protection mechanisms
9.
LED indicator for Status and Error codes
Index
Description
LED Color Indicator
Definition
Green Blue
Red
1
Initial
Power-on
ON
Off
Off
Ready to be used
after 5 seconds of
Power-On
Initialization.
When LED is
Green, it is ready
to be used.
2
Connecting
(hand-
shaking
with EV)
Flashes
Off
Off
After self-test, the
device is READY to
plug into Electric
Car socket. During
connection, there
is a handshaking
process with EV
which the Green
LED will flashes
quickly.