Safety Warning 

-

 

The voltages inside UPS may be hazardous. Do not attempt to 
disassemble the unit. The unit contains no user serviceable parts. 
Only factory service personnel may perform repairs. 

-

 

Internal battery voltage is 12Vdc. sealed, lead-acid, 6 cells battery.   

-

 

Connection to any other type of receptacle other than a two-pole, 
three-wire grounded receptacle may result in shock hazard as well as 
violating to local electrical codes. 

-

 

In the event of an emergency, press the OFF button and disconnect the 
power cord from the AC power supply to properly disable the UPS. 

-

 

Do not allow liquids or any external objects to enter the UPS. Do not 
place beverages or any other liquid-containing vessels on or near the 
unit. 

-

 

This unit is designed for installation in a controlled environment 
(temperature controlled, indoor are free of conductive contaminants). 
Avoid installing the UPS in locations where there is static or flowing 
water, or excessive humidity. 

-

 

Do not plug the UPS input into its own output. 

-

 

Do not attach a power strip or surge suppressor to the UPS. 

-

 

Do not connect non-computer-related items, such as medical 
equipment, life-support equipment, microwave ovens, or vacuum 
cleaners to UPS. 

-

 

To reduce the risk of overheating the UPS, do not cover the UPS 
cooling vents and avoid exposing the unit to direct sunlight or installing 
the unit near heat emitting appliance such as air heaters or furnaces. 

-

 

Unplug the UPS prior to cleaning and do not use liquid or spray 
detergent. 

-

 

Do not dispose the batteries into fire as they may explode. 

-

 

Do not open or mutilate the battery or batteries. Released electrolyte 
is harmful to the skin and eyes. It may be toxic. 

-

 

A battery can present a risk of electrical shock and high short circuit 
current. The following precautions should be observed when working 
on batteries: 
1)

 

Remove watches, rings, or other metal objects from the hands. 

2)

 

Use tools with insulted handles. 

3)

 

Wear rubber gloves and boots. 

4)

 

Do not lay tools or metal parts on the top of batteries. 

Summary of Contents for DN-170063

Page 1: ...DIGITUS Line Interactive 600 2000 VA UPS Systems Quick Installation Guide DN 170063 DN 170064 DN 170065 DN 170066 DN 170074 DN 170075 DN 170076 ...

Page 2: ...ere is static or flowing water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not connect non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to d...

Page 3: ...this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Beware of possibility of electric shock when disconnecting of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected from the plus and minus terminals of the battery when mainten...

Page 4: ... the 1st to 4th green LEDs gradually lighting indicating load level 1500VA 2000VA Battery Mode Yellow LED flashing 600VA 1000VA The left green LED flashing the 1st to 4th green LEDs gradually lighting indicating batter capacity 1500VA 2000VA Fault Mode Red LED lighting DN 170063 DN 170064 DN 170065 DN 170074 600 VA 800 VA 1000 VA ...

Page 5: ... lights 5 Battery level battery capability 6 Low battery when battery voltage is low this LCD symbol flashes 7 Load level Load percent 8 Over load when there is output over loading this LCD symbol flashes 9 Fault mode this LCD symbol lights when UPS in fault mode such as output shorted over charge over load DN 170066 DN 170075 DN 170076 1500 VA 2000 VA ...

Page 6: ... of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged However some charge may be lost during shipping and the battery should be recharged prior use Turn on the UPS plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical devices such as computers monitors...

Page 7: ...ent where the ambient temperature or humidity is high On the other hand place the UPS away from the monitor at least 20cm to avoid interference 4 Connection Plug the UPS into a grounded receptacle Then connect one device into each of the power receptacles supplied on the back of the UPS 5 Turn On Off In order to turn on the UPS unit press the power switch lightly To turn off the UPS unit press the...

Page 8: ...r switch again Alarm buzzer beeps continuously when AC supply is normal Overload of the UPS Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 6 8 hours 3 Battery defect due to high temperature operation environment or improper operation...

Page 9: ...e In this case the user may be required to take appropriate measures Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is missing you can request it by post under the below mentioned manufacturer address www assmann com Assmann Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid Germany ...