INSTALLATION 

INSTALLATION

 

MONITOR LOCATION 

The monitor has to be mounted in the compartment at a well visible place with 
the attaching clip being in lower or upper position using 2 plate screws. Avoid 
direct  sunlight  to  reach  the  display.  The  most  favourable  location  for  the 
monitor is right under the compartment roof. 

 

The monitor is to be connected to the 12V system of the power machine 
behind a minimum 1A fuse with regard to polarity (red = positive, blue =  
negative).  The  wire  between  the  connection  point  and  the  12V 
accumulator of the power machine should be as short as possible.  

 

Connect the sensors’ extension cable to the monitor.  

 

Do not share power supply with devices that may cause interference (fans, 
magnetic valves, etc.).  

 

Welding works are only allowed when both power cables of the monitor 
are disconnected from the tractor’s electronic system. 

 

CONTROL DEVICE

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DMS 06 PLANTER  MONITOR

1

2

3

4

5

6 ROWS

AUTO OFF

sec

TEST

P

OWER

OUT

DIGITROLL

S tring Circuitry

0,25

0,5

0,75

1

1,5

2

INTELLIGENT  SENSOR  TECHNOLOGY

Horn 

ON and TEST button 

(searching seed 

sensors, checking 

dust level) 

Stand-by signal 

(red light) 

Switched on, 12V OUT=  continuous light 
Sensor search 

=  darkens for a short time 

Cable short 

=  dark during operation 

Switched off 

=  dark 

error = red light 

Selectable time 

intervals (0.25 – 2 sec) 

Number of seeder 

elements (1-6) 

Adjusting sensitivity of 

error indication 

(max. time period of 

seed shortfall) 

Summary of Contents for DMS 06

Page 1: ...DMS 06 PLANTER MONITOR INSTRUCTION MANUAL...

Page 2: ...SYSTEM DRAFT 2...

Page 3: ...1000 tipusf gg fejkialak t ssal magvezet cs h z DS 2000 tipusf gg fejkialak t ssal csoroszly hoz DMS06 PLANTER M ONITOR 1 2 3 4 5 6 RO WS A UTO OFF sec TEST P O E R W O U T DIGITROLL S tring Circ uit...

Page 4: ...sensor modules infrared sensors Modules in chain linked array up to 6 rows Modules are interchangeable their sequence is determined when connected Harness free network easy cabling and mounting SYSTEM...

Page 5: ...sors extension cable to the monitor Do not share power supply with devices that may cause interference fans magnetic valves etc Welding works are only allowed when both power cables of the monitor are...

Page 6: ...If seed flow is continuous the LED is off In case flow is interrupted e g because of blockage incorrectly set seed sweeper low vacuum etc for longer than the previously set shortfall tolerance time v...

Page 7: ...leaned at the end of each season even if no dust is indicated and extension cable connectors must be sealed off watertightly Monitor cannot be exposed to direct moisture and temperatures below 20 C an...

Page 8: ...cause of power outage The monitor does not detect some or all of the seed sensors during the Test Some of the seed sensor LEDs is off Damaged connecting leads or loose connector causes disturbance in...

Page 9: ...6 13 20 27 41 55 12 3 6 10 13 20 27 12 5 11 17 23 34 46 14 2 5 8 11 17 23 14 4 9 14 19 29 39 16 2 5 7 10 15 20 16 4 8 13 17 26 34 18 2 4 6 9 13 18 18 3 7 11 15 23 30 20 2 4 6 8 12 16 20 3 6 10 13 20...

Page 10: ...TABLE OF SEED SHORTFALL 10...

Page 11: ...TABLE OF SEED SHORTFALL 11...

Page 12: ...TABLE OF SEED SHORTFALL 12...

Reviews: