MAINTENANCE, STORAGE
24
THE MONITOR INDICATES BLOCKAGE AT A SEED
MODULE FOLLOWING TEST AND EVEN AFTER CLEANING
Defected seed module.
Troubleshooting: insert a long stick inside the seed sensor. If LED gets dark
for a second: it works. If not: sensor is defected.
THE MONITOR INDICATES IRREGULAR SEED DROPS
WHEN SEEDER STOPPED
Seeds or seed fragments picked up accidentally by the air-flow are detected by
the seed sensor. Sensitivity was set too high – adjust higher time limit to
reduce sensitivity.
THERE IS NO SEED DETECTION AT A PROPERLY
WORKING SEEDER, TEST FINDS SEED MODULES, NO DUST
INDICATED
•
Small sized seeds at low rate seeding – adjustment to small seed size and
missing seed time interval to higher.
•
Module is defected, check it by blinking LED with a long stick inserted
inside.
MAINTENANCE, STORAGE
•
The most important is keep cables and connectors unhurt and check
then regularly.
•
Always clean sensors at the end of seeding season, close the end of
extension cable with the waterproof seal.
•
Do not expose the monitor to direct water, do not store it under –20 C
and above + 40 C temperature, protect it from excessive heat and dust.
Remove the monitor from the cabine for winter and store at a dry,
vapourfree place.
•
Protect monitor front, display and buttons from strong mechanical
impacts. Clean the monitor with a slightly wet wipe.
•
There is no battery in the monitor and there are no other parts that
require maintenance.
WARRANTY PROVIDED
See attached warranty card.