background image

 

 

    

 

 

 

 

1. 

Setup:

 

a. 

Turn on 

the torque wrench by pushing the  

M

 key.           

 

b

.  

In 

TORQUE mode  

 

     

Press the 

key to view the units of measure.    

     Repeatedly push the 

U

 key to display the desired units 

     of measure, ft-lb, in-lb or Nm. 

 

TORQUE 

- Displays torque value in real time when torque is 

loading and also shows peak torque when torque is released. 

 

c.  

Manual Power off:  

Hold the 

M

 key for more than 5 sec  

 

d.   Push the 

▲ 

or 

▼ 

key to view the TARGET TORQUE  

      value.  Use these same keys to increase or decrease to 

      the desired value.   

      During loading, the torque wrench will display applied  

      torque in real time.  The yellow LED and the buzzer will  

      begin to pulse at 80% of TARGET TORQUE, and getting  

      faster as the TARGET TORQUE value is approached.   

2.  

Application:

 

a. With the power is on, insert the torque wrench driver into 

the socket. 

b. Apply torque load to the fasterner in either CW or CCW 

directions. During loading, the torque wrench will display 

applied torque in real time.   

c. When the applied torque is within 4% of the TARGET 

TORQUE value, the green LED, buzzer and vibrator 

(optional) will output continuously.  Stop applying torque, 

as the installation is complete.  

    

Release Indications:

 

    Should the applied torque exceed the TARGET 

TORQUE value by more than 4%, the red LED and 

buzzer will trigger.  If the torque applied is exceeded 

125%  of torque range, the display will indicate 

OVER 

TORQUE.

 

 

Temperature Drift: 

 

± 0.0015%/F 

Storage Temperature

 

 

  0ºF to 125ºF 

Operating Temperature

 

  40ºF to 110ºF 

Humidity

 - 

 

 

up to 90% non-condensing 

 

    

Re-Order Components :

 

 

DWU Torque wrench USB 

      

P/N DWU-XXXX

 

 

User 

s Guide  

 

      

P/N DTS-UG–

 

DWU

 

 

Warning

 - 

Risk of flying particles. 

 

Read this entire User

s Guide before using 

this   torque wrench  

 

Always follow good professional tool practices. 

 

Wear Safety goggles

.   

 

Insure that all equipment is in good working 

order and that ratings of the torque wrench, 

tools and drives exceed the torque being 

applied.   

 

Never use the torque wrench with the power 

off.   

 

Never initiate ZeroTare with torque applied. 

 

Do not use the wrench as a breaker bar to 

loose nuts, bolts or fasteners 

 

Save these instructions. 

The 

“DWU”

 series of electronic torque wrenches establishes a 

new standard in threaded faster installation tools.  It features the 

latest state-of-the-art sensing and micro-controller technology in a 

robust tool designed for the professional mechanic. 

 

The 

DW 

series f/-1% accuracy of torque reading between 

10% and 100% of full scale in both CW and CCW directions 

which exceeds the ASME B107.28 Standard.  The wrench is 

usable down to 5% of full scale at +/-3% of reading precision.  Its 

integral 36-tooth ratchet drive provides strength as well as versa-

tility in use.  Three wrench sizes are available, providing 1/4in, 

3/8in and 1/2in square drive ratchet heads, covering 20 in-lb to 

250 ft-lb torque capacity. 

The wrench is powered by two easily replaceable AA Alkaline 

cells.  This battery provides up to 400 hours of continuous opera-

tion.  This electronic torque wrench is intended for use in industri-

al, aerospace, automotive repair, reliability labs and quality assur-

ance environments.   

 

 

Keypad Functions: 

   Power ON - 

 M 

key 

   

U

 

 

-

  Unit Selection -  ft-lb, in-lb or Nm

 

        - 

Zero Tare Torque  (Press and hold key 3 seconds)  

   

M

 

 

-

 Mode - Manual power off, (Press and hold key 3 seconds) 

   ▲ 

Increase TARGET TORQUE value 

           (Press and Hold Key for rapid scrolling Up ) 

   

 - 

Decrease TARGET TORQUE  value 

          (Press and Hold Key for rapid scrolling Down) 

Automatic Power OFF  after 5 minutes of idle time. 

Note: For resolutions and decimal point, see table on back. 

 

 

 

         

 

Important Safety Instructions

 

Introduction

 

Operator Instructions

 

      How to Print, Erase and Exit

 

Before use of the tool, set up the driver “

USB Driver.exe

” 

and open up the program “

DTS_USB.exe

”, which will 

both be located on the flash drive that is sent with this 

product.

 

When the .exe file is opened press the “BEGIN” button, 

the “Connection Status” box will then read “

Ready for 

transmission

”.

 

Open up Microsoft Excel to record the data, placing the 

cursor at the location you wish to save the data at. 

 

SIDE NOTE: 

 

If you move the cursor and click on a different location 

while the device is still storing data, the data will move to 

the new location and continue to store data. 

 

To store data, apply torque to the device to the target 

torque you wish to store and then release the pressure. The 

number that was reached will then begin to blink on the 

display. You may then store the data by pressing the down 

arrow key, or you can immediately upload the data (if al-

ready connected to the computer) by pressing the up arrow 

key. 

 

The display will flash the number for the next 15 seconds. 

After 15 seconds have elapsed the meter will once again 

read 

0.0

.

 

After storing data, press the “M” key which will prompt 

one of the following commands: “PRINT”,  “ERASE”, or 

“EXIT”.

 

When you wish to the print the data that has been down-

loaded to the device, press the “M” key until the device 

reads “PRINT”, and press the “U” key.

 

When you wish to the erase the data from the wrench, 

press the “M” key until the device reads “ERASE”, and 

press the “U” key.

 

If you wish to continue to make measurements or simply 

wish to exit the choosing screen, press the “M” key until 

the device reads “EXIT”, and press the “U” key.

 

This command screen will display any of the following 

 

three commands for 60 seconds. After the 60 seconds has 

 

elapsed, the device will return back to measuring mode.

 

SIDE NOTE: If the battery is removed from the device, 

any previously stored data will be automatically deleted.

 

SIDE NOTE: The maximum amount of data entries that 

can be stored at a time is 330 entries

 

Reviews: