1.  Attach HDMI cables from video source to Transmitter and from 

Receiver(s) to display(s). 

2.  Attach Ethernet cables connecting between Transmitter and 

Receiver(s). 

3.  Connect and power on Transmitter and Receiver(s). Do not 

switch on displays until resolution settings made. 

4.  Define resolution of monitor(s) attached to Receiver 

  Select desired resolution from one of the option from table 

below. Adjust “EDID DIP” switch, refer to table below. “0” 
represents switch down. “1” represents switch up.   

 

  After DIP Switch set, press “SET” button to register setting. 

NOTE: Receiver factory default setting is Bypass mode. All 
monitors receive the same resolution setting as Transmitter 
setting. (Go to Step 5 for Transmitter EDID setting). 

NOTE: Transmitter and Receiver at factory default- all attaching 
monitors at both Transmitter and Receiver receive 1080p 60Hz 
video. 

NOTE: Receiver sets Bypass mode, Transmitter sets Read 
LOCAL OUTPUT EDID- Transmitter automatically reads EDID 
from attached monitor and feeds the same setting to all monitors 
attached to Receiver. When no local monitor directly connected 
to Transmitter, EDID will be undetectable and may result 
display error 

Summary of Contents for ET-HST1300

Page 1: ...HDMI 300m UTP Extender Series ET HST1300 HDMI 300m UTP Extender Transmitter 1 port ET HSR1300 HDMI 300m UTP Extender Receiver 1 port ET HST4300 HDMI 300m UTP Extender Transmitter 4 port ...

Page 2: ...dapter x 1 AC Power Cord x 2 Quick Installation Guide x 1 ET HSR1300 Receiver Unit x 1 Locking DC 5V 2A Power Adapter x 1 AC Power Cord x 1 Quick Installation Guide x 1 ET HST4300 Transmitter Unit x 1 Locking DC 5V 2A Power Adapter x 1 AC Power Cord x 1 Quick Installation Guide x 1 ...

Page 3: ...ET HST1300 HDMI 300m UTP Extender Transmitter 1 port ET HST4300 HDMI 300m UTP Extender Transmitter 4 port ...

Page 4: ...ET HSR1300 HDMI 300m UTP Extender Receiver 1 port ...

Page 5: ...switch up After DIP Switch set press SET button to register setting NOTE Receiver factory default setting is Bypass mode All monitors receive the same resolution setting as Transmitter setting Go to Step 5 for Transmitter EDID setting NOTE Transmitter and Receiver at factory default all attaching monitors at both Transmitter and Receiver receive 1080p 60Hz video NOTE Receiver sets Bypass mode Tran...

Page 6: ...et press SET button to register setting NOTE Transmitter factory default setting is 1080p 60Hz video NOTE Receiver sets Bypass mode Transmitter sets Read LOCAL OUTPUT EDID Transmitter automatically reads EDID from attached monitor and feeds the same setting to all monitors attached to Receiver When no local monitor directly connected to Transmitter EDID will be undetectable and may result display ...

Page 7: ......

Reviews: