DIGITEN DTC-102 Manual Download Page 5

-3-

View setting value

When the controller is working normally, short press SET and you can look at the

parameter values in order

.

Setting Instruction

How to change temperature unit

1.

Long press SET button until

and

flash

2.

Press

or

to switch the desired temperature unit

3.

Long press SET button for 3S again to save and exit

Notice: When temperature unit value has been changed, all the setting value will be

recovered to factory settings.

Set the SV value

1.

Press and hold SET button until the

icon appears on the LCD, this will take over 3

seconds.

2.

Short press SET button again until

flashing.

3.

Press the

and

button to adjust the current SV value.

4.

Press Set button to save and exit

Summary of Contents for DTC-102

Page 1: ...Thermostat Manual DTC 102 www digit en com service digit en com...

Page 2: ...ge 4 Setting Other Functions page 4 How to restore default setting page 5 Function range and setting page 5 Function Introduction page 5 Cooling Mode page 6 Heating Mode page 6 High Low Temperature Al...

Page 3: ...ms are available Over temperature and sensor fault alarm Heating Cooling return difference could be set separately for refrigeration and heating to protect temperature controller from violent change C...

Page 4: ...ifferential 4 CD Cooling Differential 5 AL Low Temperature Alarm 6 AH High Temperature Alarm 7 DP Time of Compressor Delay Starting 8 CA Temperature Calibration 9 Setting Mode 10 Cooling Mode 11 Heati...

Page 5: ...the desired temperature unit 3 Long press SET button for 3S again to save and exit Notice When temperature unit value has been changed all the setting value will be recovered to factory settings Set t...

Page 6: ...ating start point SV set value HD heating differential Note Please do not connect any load heating or cooling equipment before you set parameters How to restore default settings Keep pressing SET key...

Page 7: ...HD 30 so Csp SV CD 27r Hsp SV HD 22 C When current temperature PVS 27 Csp the temperature controller enter cooling mode and the cooling equipment start working When the temperature is less than 25 SV...

Page 8: ...rigeration operations is less than preset delay lime the equipment won t start refrigeration until achieve the preset delay time Delay time will be recorded at the moment that refrigeration stops 5 te...

Page 9: ...Compressor is working Now PV current temperature is higher or equal to Csp Cooling Start Point you could enter Setup Mode directly or wait 3 minutes until it doesn t flash green light before setting t...

Page 10: ...oducts are guaranteed to the original owner for one year against defects in workmanship and materials Please contact us service digit en com www digit en com support WARNING Do Not Overload This unit...

Reviews: