Digitek DT-2844R Operation Manual Download Page 2

 

                                                                                               

 

1.

   

ATIONSAFETY INFORM

 

SAFETY SYMBOLS 

  Warning! 

Dangerous Voltage (Risk of electric shock). 

  Caution!

 Refer to the user’s manual before using this Meter. 

  Double Insulation. 

 

  Alternating Current (

AC

).

 

  Direct Current (

DC

).

 

  Either 

DC

 or 

AC

.

 

  Ground

 (maximum permitted voltage between terminal and ground). 

          US Safety Standard. 

      European Safety Standard 

The

 

symbol indicating separate collection for electrical and electronic 

equipment. 
 

  The RESPONSIBLE BODY shall be made aware that, if the instrument 

is used in a manner not specified by the manufacturer, the protection 
provided by the instrument may be impaired. 

  The finger or any part of your body shall not be beyond the barrier of 

    the test probe when measuring. 

    Individual protective equipment must be used if HAZARDOUS LIVE parts in the 

installation where measurement is to be carried out could be ACCESSIBLE. 

 
The following safety information must be observed to insure maximum personal safety during 
the operation at this meter. 

1.1

   Do not operate the meter if the body of meter or the test lead look broken. 

1.2

   Check the main function dial    and make sure    it is at the correct position before each 

measurement. 

1.3

   When making current measurements ensure that the circuit not “live” before opening it in 

order to connect the test leads. 

1.4

   Do not perform resistance, capacitance, temperature, diode and continuity test on a live 

power system. 

1.5

   Do not apply voltage between the test terminals and test terminal to ground that exceed 

the maximum limit record in this manual. 

1.6

   Exercise extreme caution when measuring live system with voltage greater than 60V DC 

or 30V AC. 

1.7

   Change the battery when the “

” symbol appears to avoid incorrect data. 

1.8

   Use the DMM indoor, altitude up to 2000m and temperature 5°C to 40°C. 

Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 
50% relative humidity at 40°C. 

1.9   

In locations subject to radio frequency interference, the product may malfunction and it 

resets automatically when leaving this environment. 

 

2.

 

SPECIFICATIONS 

2.1 GENERAL SPECIFICATIONS 

Display:    LCD with a max. reading of 4000. 
Range control:    Auto range & Manual range control 

 

 

Summary of Contents for DT-2844R

Page 1: ...4 4 4000 COUNTS AUTO 000 COUNTS AUTO 000 COUNTS AUTO 000 COUNTS AUTO RANGE RANGE RANGE RANGE AC DC TRUE AC DC TRUE AC DC TRUE AC DC TRUE RMS RMS RMS RMS DIGITAL MULTIMETER DIGITAL MULTIMETER DIGITAL...

Page 2: ...Do not operate the meter if the body of meter or the test lead look broken 1 2 Check the main function dial and make sure it is at the correct position before each measurement 1 3 When making current...

Page 3: ...ICATIONS Accuracies are of reading number in last digit at 23 5 C 75 RH 2 2 1 DC Voltage Overload protection 600V DC or AC rms Impedance 10M More than 100M on 400mV range 2 2 2 AC Voltage AC DC True R...

Page 4: ...c each 15min maximum 2 2 5 Resistance Overload protection 250V DC or AC rms 2 2 6 Capacitance Overload protection 250V DC or AC rms 2 2 7 Diode and Audible continuity test Range Description Test condi...

Page 5: ...r duty cycle 3 4 Resistance Measurement 1 Connect the black test lead to COM socket and red test lead to the V Hz socket 2 Set the selector switch to desired position 3 Press SELECT key to choose Resi...

Page 6: ...s non effective on Hz DUTY measurement It can not display bar graph on Relative measurement mode 3 11 Auto Manual range The auto range mode is a convenient function but it might be faster to manually...

Page 7: ...bottom case and fasten the screws then close the battery cabinet cover and fasten the screw 6 MAINTENANCE 1 Before open the battery cover disconnect both test lead and never uses the meter before the...