Control Keypad Operation (continued)

Exit IR Learning Mode

Enter IR Learning Mode

Programming the Display On and Display Off Keypad Functions

Press and hold the HDMI button on the Control Panel for three seconds. The ON and OFF 

buttons will light up.

Follow the instructions below to enter IR learning mode to program IR ON / OFF commands so 

the DL-RMKTC1H1V-W keypad can control display power.

Press  and  hold  the  VGA  button  on  the  Control  Panel  for  three  seconds.  The  ON  and  OFF 

buttons will go dark.

1.  Press the ON button, and it will start to flash.
2.  Point the display remote at the Control Panel IR sensor and the press the Power On button 

on the remote. The ON button on the Control Panel will stop flashing.

3.  Press the OFF button, and it will start to flash.
4.  Point  the  display  remote  at  the  Control  Panel  IR  sensor  and  the  press  the  Power  Off 

button on the remote. The OFF button on the Control Panel will stop flashing.

Testing Display On / Off IR Control on Control Pad

To test the IR On and Off control functions for your display or projector simply quick press 

the ON and OFF buttons on the control pad. Your display or projector should respond to the 

stored IR commands appropriately, if not repeat steps 1-4 from ‘Programming the Display On 

and Display Off Functions’.

IR Display Control - IR Learning Mode Configuration

Summary of Contents for DL-RMKTC1H1V-W

Page 1: ...the wall plate transmitter and the receiver The wall plate control module connects to the wall plate transmitter with a second Category 6 cable All the power needed for the system is provided by the r...

Page 2: ...fications may cause damage deterioration or malfunction Refer all servicing to qualified service personnel To prevent fire or shock hazard do not expose the unit to rain moisture or install this produ...

Page 3: ...oC TCP IP A B C D E F G H I J K L 1 Firmware Update Port 2 System Power Indicator 3 HDBaseT Link Indicator 4 HDCP Status Indicator 5 Receiver Power Indicator A Network Port B HDBaseT Input and PoC Out...

Page 4: ...DBT OUT POWER RS232 DL RMKTC1H1V W TX Transmitter 1 Power Indicator and Source Select Button 2 Link and HDCP Status LEDs and Reset Button 3 VGA Audio Input with Activity Indicator 4 USB Port to Host P...

Page 5: ...DL RMKTC1H1V W PAD Control Pad A B 1 Mic Source Indicator 2 System Display On Button 3 HDMI Input Select Button 4 IR Receiver 5 Multifunction Volume Control with Volume Level Indicator 6 System Displ...

Page 6: ...KTC1H1V W receiver Connect the display TX signal to Rx on the DL RMKTC1H1V W extender To ensure proper performance of the DL RMKTC1H1V W it is recommended that you use solid core Category 6 F UTP cabl...

Page 7: ...Speaker Wiring Configurations 4 Load with 4 Speakers 4 4 4 Load with 8 Speakers 8 8 8 8...

Page 8: ...to the IR receiver port of the display 9 If the display is to be controlled via RS232 plug the 3 pole terminal plug end of the included RS232 cable into the RS232 port on the Receiver and the DE9 end...

Page 9: ...MKTC1H1V W is 192 168 0 178 This can be changed in the Network settings To change the settings of the web browser interface or program RS232 commands for the display log into the DL RMKTC1H1V W as an...

Page 10: ...e display on or off System Turn the system on or off Volume Mute and unmute audio sources Volume may be changed by pressing the or buttons or by dragging the volume slider To enter the configuration s...

Page 11: ...lled via RS232 I O Mode Select Select whether the contact closures need to be normally open N O or normally closed N C to mute the audio output for integration with a mass notification system Floor As...

Page 12: ...time in seconds between the Display ON and Input Select commands This delay may be between 1 and 100 seconds The default time is 5 seconds Baud Rate Select the baud rate necessary to communicate with...

Page 13: ...ration Tab This tab defines the scaled output resolution for the DL RMKTC1H1V W Choose a resolution setting compatible with the connected display Output will scale automatically once selection has bee...

Page 14: ...CP IP Address Enter the IP address for the system Subnet Mask Enter the subnet mask for the system Gateway Enter the gateway address for the system Save Cancel Saves or cancels changes made to this sc...

Page 15: ...or can be programmed so system power and display power can be controlled separately By default the DL RMKTC1H1V W is set to control the connected display by IR The adjustment in the web GUI for this...

Page 16: ...isplay remote at the Control Panel IR sensor and the press the Power On button on the remote The ON button on the Control Panel will stop flashing 3 Press the OFF button and it will start to flash 4 P...

Page 17: ...W system can be configured to synchronize with the power of the display simultaneously or can be programmed so system power and display power can be controlled separately After the RS232 settings are...

Page 18: ...he connected displays RS232 ON or OFF command sets into the DL RMKTC1H1V W navigate to the COMMAND page and enter in the command sets and proper RS232 settings according to the display manufacturers s...

Page 19: ...e Volume knob clockwise will raise the volume counterclockwise will lower the volume Pressing the Volume knob will mute or unmute the current audio source Pressing and holding the Volume knob for thre...

Page 20: ...s an alternative method to control the system without having to interact with the Control Panel The default IP address of the DL RMKTC1H1V W is 192 168 0 178 This can be changed in the Network setting...

Page 21: ...VGA Switch between HDMI and VGA inputs Display Turn the display on or off System Turn the system on or off Volume Mute and unmute audio sources Volume may be changed by pressing the or buttons or by...

Page 22: ...e Control Panel for three seconds As soon as the buttons are released they will light up while the upload is in progress Remove the thumb drive from the Configuration port once the buttons go dark FCC...

Page 23: ...up to 190Mbps Contact Closure NO and NC for system mute HDBaseT Signal Characteristics Maximum Distance 30 m 98 ft Cable Requirements Continuous solid core Category 6 or greater with TIA EIA 568B cri...

Page 24: ...CO 80921 Toll Free 800 530 8998 Fax 719 260 0075 www libav com Digitalinx is a brand of Liberty AV Solutions Thank you for your purchase For Technical Support please call our toll free number at 800...

Reviews: