DigitaLinx DL-ARK Series Quick Install Manual Download Page 3

DL-ARK Quick Guide

3

Connectivity Instructions

1.  Verify all components included with the DL-ARK A/V system are present before installation.
2.  If the receiver is going to be permanently mounted to a surface or A/V box, attach the included 

mounting brackets with the supplied screws.
3.  Turn  off  power  and  disconnect  the  audio/video  equipments  by  following  the  manufacturer’s 

instructions. 
4.  Connect Category 6 or greater twisted pair cable between the DL-ARK control pad and transmitter 

up to 30m / 100’, then connect a Category 6 or greater cable between transmitter and the receiver up 

to 70m / 232’. TIA/EIA-568B straight-through wiring connections must be used.
5.  Connect an HDMI cable no greater in length then 5m  / 16’ and any desired IR or RS232 control 

accessories between the display and the DL-ARK receiver.
6.  Connect an HDMI cable no greater than 5m  / 16’ in length between the source and the DL-ARK 

transmitter.
7.  Mount the keypad and wall plate transmitter.
8.  Connect the included power supply to the DL-ARK receiver and lock the power supply to the power 

connector by twisting the locking collar clockwise. 
9.  Power on attached audio/video devices.

Cabling Wiring Requirements

Twisted Pair Wiring

Use TIA/EIA-568B wiring for Category 6 

connection between send and receive 

units.

HDBaseT Cabling

To ensure proper performance of the DL-ARK, it is recommended that you use solid core, shielded 

Category 6 F/UTP cabling at a minimum between control pad and transmitter and between transmitter 

and receiver. Category 5e F/UTP may perform well but may not support power over HDBaseT reliably 

over longer distances. 

For optimized HDBaseT performance use the following Liberty Wire and Cable branded cabling;

 

Category 6 plenum; 

24-4P-P-L6SH

 

Category 6A plenum; 

24-4P-P-L6ASH

 

Category 6 NON-plenum; 

24-4P-L6SH

 

Category 6A NON -plenum; 

24-4P-L6ASH

When using shielded category cabling 

ALWAYS

...

     ....use shielded connectors

     ....properly ground the category cable