Settings related to fuel theft alarm.
Parameter Required
value
Comments
P40
1-255
Enables fuel theft alarm for first tank and set theft alert trigger threshold
P41
0,1 or 2
Theft alarm mode (common for both fuel tank alarms)
P42
+xxxxx
User’s phone number
1 (to receive alert SMS)
P43
0-2
Fuel level change direction (for first fuel tank)
P44
0-250
Fuel theft alarm activation time (common for both fuel tank alarms)
P45
1-255
Enables fuel theft alarm for second tank and set theft alert trigger threshold
P46
0-2
Fuel level change direction (for first fuel tank)
P48
+xxxxx
User’s phone number 2 (to receive alert SMS)
P52
0 or 2
Allow fuel measurement when ignition is switched OFF
Vehicle’s battery supervisor
.
It is possible to enable a battery voltage supervisor; in this case driver will be informed about voltage
drop via SMS message.
How it works?
Each time ignition is switched OFF, terminal starts to monitor a vehic
le’s battery voltage
. In case if
voltage level drops below predefined value and remains this condition more than 30 seconds, than
terminal sends SMS alert to predefined numbers. In case is there are short voltage drops, terminal will
ignore it.
To setup battery supervisor, do as follows;
1.
Define phone numbers to receive SMS alert message by setting parameter
P42
and/or
P48
.
2.
Set voltage threshold to trigger low voltage alarm by setting parameter
P60.
Note!!!
In case of voltage drop detection, terminal will send only one SMS alert to each defined number after
that battery supervisor becomes passive. Switch ignition ON and then OFF to activate it again.
Settings related to battery supervisor usage.
Parameter Required
value
Comments
P42
+xxxxx
User’s phone
number to receive warning message
P60
100-255
Enable battery monitor, set alarm trigger threshold