background image

 

2/5/2007 

To contact Technical Support please call 770-420-1350 

 

Operating the TheaterScope 

 

Safety Note 

Be sure to keep hands & fingers and any loose clothing away from any moving parts 
 

Automatic mode 

The TheaterScope powers-up in automatic mode. On power-up the LED flashes green multiple 
times, and then turns a solid color when the unit is ready for operation.  
Depending on the position of the TheaterScope, the led will be different colors. 
Solid Green = Home position. 
Solid Red = other limit of travel. 
Solid Amber = in between limits. 
The Led will blink with the Amber color while the TheaterScope is moving. 
 

Control 

You may use any of the following means to control the TheaterScope: 

 

Infrared Control 

 

RS-232 Serial / Computer Control 

 

Single Latching Relay 

 

Programming the TheaterScope 
 

 

To enter Programming mode: 

 
1. Hold down 

buttons 1, 2, and 3

 while powering up the TheaterScope. The LED will flash 

green, and then turn red to indicate that you have entered programming mode. Release all 
buttons when the LED turns a solid red.  

2. Test the unit by pressing buttons 2 or 3. It should move only when the button is depressed. 

The TheaterScope will stop when the button is released. In manual mode the led colors are 
the same as they are in automatic mode. 

3. The TheaterScope has a default setting of operating on a LENS-CENTERED projector (i.e. 

Mercury, Titan).  

Only if your projector is LENS-LEFT (i.e. dVision), make the 

following programming change: 

 

While in programming mode, hold button 1 for 10 seconds until the led flashes, then 
release button 1.   This will reverse the direction of the TheaterScope to function 
properly with your LENS-LEFT projector. 

 

Programming 

Buttons 