background image

Digital Monitoring Products 

XR500/XR500N Installation Guide

2

INTRODUCTION

Panel Features

2.1 Description

The DMP XR500/XR500N Command Processor™ Panel is a versatile 12 VDC, combined access control, burglary, and 

Þ

 re communicator panel with battery backup. The XR500/XR500N provides eight on-board burglary zones and two 

on-board 12 VDC Class B powered zones. The powered zones have a reset capability to provide for 2-wire smoke 
detectors, relays, or other latching devices. The XR500/XR500N can communicate to one or two DMP SCS-1/SCS-1R 
Receivers using digital dialer or network communication, or to non-DMP receivers using the Contact ID format.

Figure 1: Typical XR500/XR500N System Con

Þ

 guration

AC

1

2

3

4

5

6

7

8

10

11

12 13

14

15 16

17

18 19

9

20

21 22

23

24 25

26

27

28

+B

BELL GND

SMK GND

RED YEL GRN BLK

Z1

Z2

Z3

Z4

Z5

Z6

Z7

Z8 Z9+ Z9- Z10+ Z10-

AC

-B

GND

GND

GND

GND

K6

K7

Output 1

Output 2

J3

Phone Line

J10

J22
LX-Bus

Battery 
Start

J23

J21

RS-232

Power 
LED

J8

PROG

J4

Tamper

J16

Reset

Out1

Out2

Outputs 3-6

J11




6

J2

J1

Ethernet

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

Power LED

Link LED

S

*

* *

*

*

*

*

*

*

*

*

*

*

*

*

Model 481, 462N, 
462P, 462FM, and 
472 Interface Cards

Model 461 Interface 
Adaptor 

S

715 Zone 
Expander

Smoke and Heat Detector Circuits

Alarm Horns

H

H

H

FIRE

Manual Pull 

Station

Fire Bell

6155LX PIR

PIR

6155LX PIR

PIR

S

S

5845LX Glassbreak 

Detector

Door 

Contact

FIRE

Manual Pull 

Station

Window 

Contact

H

Heat 

Detector

Window 

Contact

714 Zone 
Expander

711 Zone 
Expander

521LX (T) 

Smoke 

Detector

SLR Series 

Smoke 

Detector

Single 4-Wire 

Cable

Up to 100 Zones 

and Relays on 

each LX-Bus 

717 Graphic 
Annunciator 

Module

Graphic Annunciator 

716 Output 

(Relay) 

Expander 

Exterior
Lighting

XR500/XR500N Command Processor™ Panel System

LX-Bus Expansion

Keypad Expansion Bus

711 Zone 
Expander

711 Zone 
Expander

Door 

Contact

Window 

Contact

Strobe

Roll-Up 

Doors

791, 793 Security 

Command Keypad

Proximity  

Reader

5845LX 

Glassbreak 

Detector

Single 4-Wire Cable

6155LX PIR

PIR

6155LX PIR

PIR

733 Wiegand 

Interface Module

Proximity 

Reader 

Keypad Bus - You can connect any combination of Security Command

 

Keypads, 6155LX PIRs, 5845LX Glassbreaks, or 711, 714, or 715 Zone 
Expanders.  Up to 64 zones with all 16 devices.  

790, 791, 793 Security 

Command Keypad

OVC

2.2 Zone 

Expansion

Up to 574 additional zones are available on the XR500/XR500N using DMP Security Command keypad remote zone 
capability and zone expansion modules.  The panel keypad data bus supports up to sixteen supervised device 
addresses with each address supporting up to four programmable expansion zones.
Up to 500 zones are available using the on board LX-Bus, Model 461 Interface Adaptor, 481, 462N, 462P, 462FM, or 
472 Interface Cards, and any combination of single, four, eight, or 16-zone expansion modules and single-zone 
LX-Bus™ detectors.

Note:

 Do not use shielded wire for LX-Bus or Keypad Bus circuits.  

2.3 Output 

Expansion

In addition to the two SPDT relays and four open collector outputs on the XR500/XR500N, you can also connect up to 
25 Model 716 Output Expansion Modules to each LX-Bus. These modules can provide an additional 500 programmable 
SPDT relays.
The XR500/XR500N provides 100 Output Schedules you can use for programming the 716 to perform a variety of 
annunciation and control functions. You can also assign the 716 outputs to any panel Output Options such as Fire 
Alarm, Communication Fail, or Phone Trouble Outputs.  Refer to the 716 Installation Guide (LT-0183).
The LX-Bus™ also supports the Model 717 Graphic Annunciator Module.  Each 717 module supplies 20 switched 
ground outputs that follow the state of their assigned zones.  Refer to the 717 Installation Guide (LT-0235) for more 
information.

Summary of Contents for COMMAND PROCESSOR XR500

Page 1: ...INST ALLA TION GUIDE XR500 XR500N ACCESS CONTROL COMMAND PROCESSOR PANEL LT 0681 1 04 2004 Digital Monitoring Products Inc...

Page 2: ...the installer is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the compu...

Page 3: ...4 1 Mounting the Enclosure 7 4 2 Mounting Keypads and Zone Expansion Modules 7 4 3 Connecting LX Bus and Keypad Bus Devices 8 Primary Power Supply 5 1 AC Terminals 1 and 2 8 5 2 Transformer Types 8 Se...

Page 4: ...Expansion Connector 15 1 Description 16 15 2 J22 LX Bus Header 16 15 3 LX Bus Interface Cards 16 15 4 LX Bus LEDs 17 15 5 OVC LED 17 J21 Serial Connector 16 1 Description 17 16 2 Serial Connector LED...

Page 5: ...2 23 6 Grade B Central Station 22 23 7 Bell Cutoff 22 23 8 AA Network Communication 22 UL 1635 Speci cations 24 1 System Trouble Display 22 24 2 Digital Dialer Telephone Number 22 24 3 Test Time 22 24...

Page 6: ...29 5 Local Protective Signaling Systems 26 29 6 Remote Station Protective Signaling Systems 26 29 7 Fire Protective Signaling Systems using Internet Intranet Networks 26 UL 985 NFPA 72 Chapter 2 Speci...

Page 7: ...reset zones 9 and 10 1 4 Keypad Bus You can connect up to 16 of the following supervised keypads and expansion modules to the keypad bus Alphanumeric keypads Four and or single zone expansion modules...

Page 8: ...X Bus Expansion Keypad Expansion Bus 711 Zone Expander 711 Zone Expander Door Contact Window Contact Strobe Roll Up Doors 791 793 Security Command Keypad Proximity Reader 5845LX Glassbreak Detector Si...

Page 9: ...uch as UL The System Diagrams illustrate different ways to wire the XR500 XR500N to a variety of modules Caution Notes Throughout this guide you will see caution notes containing information you need...

Page 10: ...ector Use UL Listed Power Supervision Relay rated at 12 VDC 1k Ohm s Supervised Circuit Zone 9 Zone 10 22 gauge minimum 22 gauge minimum 22 gauge minimum 22 gauge minimum RED YELLOW GREEN BLACK 1k Ohm...

Page 11: ...equires 710F Bus Splitter Repeater 716 Output Expander Provides four Form C relays SPDT and four switched grounds open collector for use in a variety of remote annunciation and control applications 71...

Page 12: ...m DMP Part Number Description Wheelock Model No 12V 801 Mini Horn MIZ 12 x 802 Multi tone Horn MT 12 24 x 803 Standard Horn NH 12 24 x 806 6 Bell 6 inch MB G6 12 x 806 10 Bell 10 inch MB G10 12 x 821...

Page 13: ...e J10 J22 LX Bus Battery Start J23 J21 RS 232 Power LED J8 PROG J4 Tamper J16 Reset Out1 Out2 Outputs 3 6 J11 3 4 5 6 J2 J1 Ethernet R L X OVC Power LED Link LED Figure 3 XR500 XR500N in Model 350A En...

Page 14: ...increases DC voltage on the wire decreases Maximum number of LX Bus devices per 2 500 feet circuit is 40 For additional information refer to the 710 Installation Sheet LT 0310 and or the LX Bus Keypad...

Page 15: ...cutoff relay is pulled in automatically For more information refer to Figure 2 6 4 Battery Replacement Period DMP recommends replacing the battery every 3 to 5 years under normal use 6 5 Discharge Re...

Page 16: ...Qty ______x Qty ______x Qty ______x 30mA 2mA 20mA ______ ______ ______ 736P POPIT Interface Module Radionics Popex POPITs OctoPOPITs Qty ______x Qty ______x 25mA ___mA ______ ______ Qty ______x Qty _...

Page 17: ...stalled to the left of the XR500 XR500N enclosure to ensure Battery and AC wire separation 24 hours of standby power 4 5 Ah Batteries 7 Ah Batteries 7 7 Ah Batteries 9 Ah Batteries 18 Ah Batteries Max...

Page 18: ...Terminal 8 receives data from keypads and zone expansion modules It cannot be used for any other purpose 8 4 Terminal 9 GREEN Terminal 9 transmits data to keypads and zone expansion modules It cannot...

Page 19: ...esistance on zone Voltage on positive terminal Open over 1300 ohms over 2 0 VDC Normal 600 to 1300 ohms 1 2 to 2 0 VDC Short under 600 ohms under 1 2 VDC 10 3 Zone Response Time A condition must be pr...

Page 20: ...725 Hochiki SIJ 24 HD 3 NS6 220 HB 3 15 33 20 725 Hochiki DCD 190 DCD 135 HD 3 NS6 220 HB 3 15 33 16 725 Sentrol ESL 429AT 521B 521BXT 521NB 521NBXT S09A 6 5 20 12 715 715 8 715 16 9 10 Sentrol ESL 42...

Page 21: ...Color Output 1 normally closed Violet Output 1 common Gray Output 1 normally open Orange Output 2 normally closed Violet with white stripe Output 2 common White with gray stripe Output 2 normally ope...

Page 22: ...hen using J22 as an LX Bus connect a DMP Model 300 4 wire Harness to the J22 4 pin header labeled LX BUS This provides the rst 100 LX Bus zones numbered 500 599 No LX Bus Interface Card is required Re...

Page 23: ...onnector indicate network operation The top Activity LED flashes green to indicate the network traffic is good The bottom Link LED flashes yellow to indicate messages are being sent and received J3 Te...

Page 24: ...to the 893A Installation Sheet LT 0135 for complete information 18 4 Noti cation The user must not repair registered terminal equipment In case of trouble immediately unplug the device from the teleph...

Page 25: ...place the Reset jumper over both of the J16 pins to reset the panel AC 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 9 20 21 22 23 24 25 26 27 28 B BELLGND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7...

Page 26: ...station phone number 20 5 Bypass Reports The Bypass Reports option must be programmed as YES for all UL burglary applications See the XR500 XR500N Programming Guide LT 0679 20 6 System Maintenance To...

Page 27: ...l be able to disarm that area UL 1023 Speci cations Household Burglar Alarm System Units 22 1 Audible Devices At least one listed audible device Ademco AB12M rated to operate over the voltage rate of...

Page 28: ...e installed in a UL AA application when NET communication is used The NET network check in time must be set from 01 to 06 minutes or AA This provides AA Central Station service When a dialer is requir...

Page 29: ...annot be less than 15 minutes See the XR500 XR500N Programming Guide LT 0679 25 6 Automatic Bell Test The Automatic Bell Test option must be programmed as YES See the XR500 XR500N Programming Guide LT...

Page 30: ...used 26 5 Grade A Bell A Grade A local audible signal appliance must be used such as Ademco AB12M bell and bell housing 26 6 Bank Safe and Vault XR500N only In addition to the requirements for Mercan...

Page 31: ...hone number unless that phone number is speci cally provided for that purpose 28 8 System Maintenance To ensure continuous satisfactory operation of any alarm system proper installation and regular ma...

Page 32: ...ours See the XR500 XR500N Programming Guide LT 0679 29 5 Local Protective Signaling Systems The DMP Model 865 866 or 867 Noti cation Circuit Module must be used on the bell circuit for detection of sh...

Page 33: ...d rated at 85 DB minimum must be used 30 3 Auxiliary Circuits At least one re alarm initiating device shall be used on the system If the voltage for the device is applied by the control unit the re al...

Page 34: ...to a maximum of twenty five 866 Modules on the XR500 XR500N panel All modules must be installed in a 340FC 349 or 350 enclosure connected by no more than 20 feet of conduit S 24 VDC 5 Amp Maximum Pow...

Page 35: ...es Install up to a maximum of twenty five 866 Modules by using the relay outputs available on the XR500 panel All modules must be installed in a 340FC 349 or 350 Enclosure connected by no more than 20...

Page 36: ...GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start J23 J21 RS 232 J8 J4 Tamper J16 Reset J11 J2 J1 GND Fault A GND Fault B A1 A1 A2 A2 Zone A...

Page 37: ...ttery Start J23 J21 J8 PROG J4 Tamper J16 Reset J11 J2 J1 Cellular Transceiver Supervised Circuit S 1 2 3 4 5 6 Panel Auxiliary Power Terminal 7 Note 1 Note 1 Telco Jack Panel Common Terminal 10 Super...

Page 38: ...1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 9 20 21 22 23 24 25 26 27 28 B BELL GND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start...

Page 39: ...itional LX Bus Modules Red Yellow Green Black LX Bus Wiring TENS ONES TENS ONES Bell Relay Address Supervisory Address Each LX Bus Module must have its own independent address ranging from 00 to 99 A...

Page 40: ...B BELL GND SMK GND RED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z9 Z10 Z10 AC B GND GND GND GND K6 K7 J3 J10 J22 Battery Start J23 J21 RS 232 J4 Tamper J16 Reset J11 J2 J1 R L X 12 VDC Relay 4 Relay 3 R...

Page 41: ...XR500 XR500N Installation Guide Digital Monitoring Products 35...

Page 42: ...CODE Enter your code number and press COMMAND The keypad display now shows ALARM SILENCE if your code allows Press the COMMAND key until SENSOR RESET appears in the display Press any top row key TROU...

Reviews: