The default for the Read Only bridge is all switches turned OFF (Read Only). 
The default for the Read/Writeable bridge is with switch #1 ON and all other 
switches (#2, #3, and #4) turned OFF (Read Write).  

When Switch #1 is OFF the bridge will operate with all writes being blocked 
(Read Only).  When switch #1 is ON the bridge will operate with writes enabled 
(Read Write).   

Switches #2 and #3 control how the unit responds when placed in Read Only 
mode and are intended for diagnostic operations and to help support operating 
systems which do not fully support read-only devices.  These switches are 
ignored if the unit is configured for Read Write. 

Switch #2 controls whether an error code is returned when a write is attempted.  
If the switch is OFF, an error will be generated when a write is attempted.  If the 
switch is on, a success code will be returned to make believe the write 
succeeded. 

Switch #3 controls what type of code page (device characteristics) is reported to 
the calling process when a device query is made.  If the switch is OFF, the code 
page is reported appropriately to indicate that the device is write protected.  If 
the switch is ON, the code page is reported as if the device was not write 
protected. 

 

Summary of Switch Settings 

Switch 1

:   OFF = Read-Only (write-blocking enabled) 

 

ON = Read-Write 

Switch 2

:   Only functions if Switch 1 = OFF, i.e., read-only 

 

OFF = Unit reports errors if writes are attempted 

 

ON = Unit suppresses errors if writes are attempted (no-error) 

Switch 3

:   Only functions if Switch 1 = OFF, i.e., read-only 

 

OFF = Unit reports Write-Protect (WP) status in code page 

 

ON = Unit suppresses Write-Protect (WP) status in code page 

Switch 4:

 Reserved 

 

Important Considerations 

 

Removal of Drives.  DO NOT

 unlock the drive bay or disconnect the hard drive 

from the FireChief while the device is powered on. 

 

Disk Cache. 

When using an operating system that cache disk writes (Windows 

95/98/ME for example), it may appear information has been written to the drive 
(via Windows Explorer for example); when in actuality the information has only 

Summary of Contents for FireChief

Page 1: ...U S E R G U I D E FireChief I M P O R T A N T R E A D M E F I R S T...

Page 2: ...is repaired modified or altered unless such repair modification of alteration is authorized in writing by DI or 2 the serial number of the product is defaced or missing Products and corporate names a...

Page 3: ...amages so the above limitation or exclusion may not apply to you DI reserves the right to modify its warranty statement at any time in its sole discretion DI will be obligated to honor any such warran...

Page 4: ...FireChief Cabling to PC 2 Drive Configuration 3 Diagnostic LED s 3 Drivers 3 Cables 3 Connecting the FireChief 4 Swapping Drives 5 Disconnecting the FireChief 5 Modifying your FireChief s Read Write C...

Page 5: ...bay labeled ReadOnly is configured as Read Only and the lower drive bay labeled Read Write is configured as read writeable Power Considerations The FireChief s internal power supply 110 220VAC auto s...

Page 6: ...is configured as Read Only The lower FireWire bridge is connected to the lower drive bay Read Write and is configured as Read Writeable Drivers No device specific drivers are required for the FireChie...

Page 7: ...pe Rack Interface Bottom Rear Drive Type Top Front SATA SATA SATA BRIDGE SATA IDE Connecting the FireChief Make sure the FireChief is powered off prior to connecting a hard drive 1 Connect the Hard Dr...

Page 8: ...lock into place 6 Reconnect FireChief to host computer Power on FireChief and reconnect the FireWire cable to the host computer s FireWire controller 7 Power on the FireChief Disconnecting the FireChi...

Page 9: ...at type of code page device characteristics is reported to the calling process when a device query is made If the switch is OFF the code page is reported appropriately to indicate that the device is w...

Page 10: ...correctly may not function properly with this device These drives are typically quite old and always less then 8 GB in size and are usually less than 2 GB in size Using a FireWire 800 Device with Mic...

Page 11: ...FireChief User Manual 13 Firmware updates If there is a need to update firmware please consult Digital Intelligence web site support pages http www digitalintelligence com support php...

Page 12: ..._____________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________...

Page 13: ...2007 Digital Intelligence Inc All rights reserved w w w d i g i t a l i n t e l l i g e n c e c o m Digital Intelligence Inc 17165 W Glendale Dr New Berlin WI 53151 P 262 782 3332 F 262 782 3331...

Reviews: