background image

7

„

 Electrical

„

 Environmental

3

General Specifications

Rated Voltage

AC 100V/AC 240V

Allowable Voltage

Range

AC 85V to AC 265V

Rated Frequency

50/60Hz

Allowable Voltage Drop

1 cycle or less

(however, pause occurrences must be more than 1 second apart)

Power Consumption

110VA or less

AC 1500V at 20mA for 1 minute

(between charging and FG terminals)

10M

 or higher at DC 500V

(between charging and FG terminals)

Voltage Endurance

Insulation Resistance

Ambient Operating

Temperature

(Cabinet Interior)

5

o

C to 50

o

C (With HDD attached)

0

o

C to 50

o

C (Without HDD)

Storage Temperature

-10 

o

C to 60

 o

C

Ambient Humidity

10% RH to 85% RH

(Non condensing, wet blub temperature : 29

o

C)

Air Purity Level

Free of dust

Pollution Degree

Pollution Degree 2

Atmosphere

Free of corrosive gas

Noise Voltage: 1500V

Pulse Duration: 50ns, 500ns, 1

µ

s

Rise Time : 1ns

(via noise simulator)

Electrostatic Discharge

Immunity

6kV  IEC 61000-4-2

Noise Immunity

(First transient burst

noise)

Power Line : 2kV  IEC 61000-4-4

COM Port : 1kV IEC6100-4-4

Vibration Resistance

9.8m/s

2

 at 10Hz to 25Hz in X, Y, Z directions for 30 minutes

With HDD attached : 4.9m/s

2

Noise Endurance

(Impulse Noise)

Summary of Contents for PS-2000B Series

Page 1: ...es unit hereafter referred to as the PS B To prevent an electrical shock be sure to connect the power cord to the PS B before connecting it to the main power supply A fire or electrical shock may result if voltages are used with the PS B that are beyond the specified range Be sure to only use the specified voltage Before opening the PS B s protective cover be sure to turn the unit s power OFF This...

Page 2: ... by the manufacturer Dispose of used batteries according to the manufacturer s instructions Be sure the unit the PS B is built into uses a UL60950 compatible equipment structure The PS2000B 41 units are CE marked EMC compliant products Complies with the following Standards Safety EN60950 EMI EN55011 Group1 Class A EN61000 3 2 EN61000 3 3 EMS EN61000 6 2 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 ...

Page 3: ... ROM 1 PS 2000B Series User Manual Driver CD Installation Guide 1 English and Japanese This Guide When you order a PS B unit built to your specifications the PS B unit s package should include an optional item Installation Guides Be sure to check each optional item s package The CD ROM contains the User Manual RAS API Reference Manual and PS 2000B Series Utility and Driver files For CD ROM content...

Page 4: ...s CD ROM in the folder titled reader Use the Explorer software to find the file Reader Eng ar505enu exe and double click on the file icon to begin the Reader installation 2 After installation begins follow the instructions given Viewing the PDF manual To view the PDF manual contained in this CD ROM follow the steps given below 1 Use the Explorer software to locate the file Manual Eng ps2000be pdf ...

Page 5: ... 12 RS 232C Connector COM1 RI 5V Changeover 13 RS 232C Connector COM2 14 RS 232C Connector COM3 RI 5V Changeover 15 RS 232C Connector COM4 16 Expansion Slots 17 Speaker Output SPEAKER 18 Line Input LINE IN 19 Mike Input MIC 20 LAN Connector LAN1 LAN2 10BASE T 100BASE TX Auto Changeover 21 Cooling FAN 22 Cover 23 Maintenance Cover 24 5V RI Changeover Switch COM1 25 5V RI Changeover Switch COM3 26 C...

Page 6: ...s Unit mm in excluding projections Side View Top View Front View 118 4 65 265 10 43 260 10 24 39 1 54 Dimensions including option units CD ROM FD Drive Unit RS 232C RS 485 Conversion Unit see PS 2000B Series User Manual ...

Page 7: ...rature Cabinet Interior 5 o C to 50 o C With HDD attached 0 o C to 50 o C Without HDD Storage Temperature 10 o C to 60 o C Ambient Humidity 10 RH to 85 RH Non condensing wet blub temperature 29 o C Air Purity Level Free of dust Pollution Degree Pollution Degree 2 Atmosphere Free of corrosive gas Noise Voltage 1500V Pulse Duration 50ns 500ns 1µs Rise Time 1ns via noise simulator Electrostatic Disch...

Page 8: ...than 4 5 kg 9 9 lb excluding projections External Dimensions W118 mm 4 65 in x H265 mm 10 43 in x D299 mm 11 77 in excluding projections Dimensions Including CD ROM FD Drive Unit W159 mm 6 26 in x H265 mm 10 43 in x D299mm 11 77 in excluding projections Dimensions Including RS 232C RS 485 Conversion Unit W139 5 mm 5 49 in x H265 mm 10 43 in x D299 mm 11 77 in excluding projections and cable ...

Page 9: ...t board The factory setting is to RI Be sure to confirm what settings will be used by the other device and set the dip switches accordingly Failure to do so can result in a unit malfunction or damage Whenever changing the PS B changeover switches be sure to first turn the PS B s power supply OFF Failure to do so can cause a PS B malfunction PS 2000B Series User Manual 1 4 1 RS 232C Interface The G...

Page 10: ...n OFF voltage 3V max Isolation Method Via photocoupler Interface Circuit Connection Example 5V R PC357 1 8kΩ 1 10W D sub 25 pin Connector DC12V to DC24V DIN0 DIN1 DIN2 DIN3 RST Cable 1 8kΩ 1 10W R switch or switching device No polarity for Sink Source input Pin No Signal Name Pin No Signal Name 1 GND 14 GND 2 5V MAX 100mA 15 5V 3 12V MAX 100mA 16 DIN3 4 NC 17 DIN3 5 DIN2 18 RST 6 DIN 0 19 DOUT1 7 ...

Page 11: ...t Be sure to operate the unit within its maximum load current If the maxi mum load current exceeds this range a malfunction or PS B damage may occur Rated Load Voltage DC12V to DC24V Maximum Load Current 100mA point Maximum Voltage Drop between Terminals 1 5V at 100mA load current Isolation Method Via photocoupler DOUT0 DOUT1 DOUT2 DOUT3 Interface Circuit Connection Example 5V R Cable D sub 25 pin...

Page 12: ...thened If high levels of vibra tion are expected and the PS B s installation surface i e an op eration panel s door etc can move i e open or close due con sideration should be given to the PS B s weight When Installing the PS B horizontally Vertical Installation 260 10 24 55 2 17 155 6 10 118 4 65 137 0 5 5 39 0 02 260 10 24 170 0 5 6 69 0 02 55 2 17 284 0 5 11 18 0 02 302 11 89 265 10 43 4 M4 4 M...

Page 13: ...lace the PS B main unit on the panel so that the bracket holes and the screw heads align Next slide the PS B down so that the main unit is supported by these attachment screws Last tighten the screws until the PS B is secured in place Do not use excessive force when tightening the main unit attach ment screws The torque required is from 1 0 to 1 2N m Attach ment Screws Attach ment Screws Vertical ...

Page 14: ...that the wires are connected correctly The torque required to tighten these screws is 0 5N m To prevent the possibility of a Ring Terminal short use a Ring Terminal that has an insulating sleeve 4 Replace the Power Input Terminal Block s clear plastic cover Use the following steps when connecting the power cord to the PS B s power terminals φ φ φ φ φ 3 2 mm or larger Max 6 0 mm Black White Green Y...

Page 15: ...ther To prevent damage from lightning connect a lightning surge absorber Constant voltage transformer Twisted pair cord PS B FG Insulating transformer Twisted pair cord PS B FG Main power source PS B power source T1 I O power source PS B I O device Main circuit power source Power device AC 200V Ground the lightning surge ab sorber E1 and the PS B E2 separately Select a lightning surge absorber whi...

Page 16: ...t be wired separately from the power circuit cable If the power cord needs to be wired together with the input output I O signal lines for any reason use shielded cord and ground one end of the shield to the PS B s FG terminal To improve noise immunity it is recommended to attach a ferrite core to the power cord 2002 Digital Electronics Corporation All rights reserved 057470H PS2000B MT01 BTHE 200...

Reviews: