background image

-1-

• Be sure to confirm that the PL unit’s power cord is disconnected prior to

installing PL-FD200, in order to prevent electrical shock.

• Do not attempt to modify the PL-FD200, due to the danger of fire or

electrical shock.

• Prior to installing the PL-FD200, be sure to read this Installation Guide's

“2. Installation” section completely to ensure that this unit is correctly
installed.

To Prevent Accidents

• Since the PL-FD200 is a precision instrument, be sure that it is neither

hit by nor pressed strongly against another object.

• Be sure that water, liquids, or metal particles are not allowed to contact

or enter this unit. Either of these may cause either a breakdown or an
electrical shock.

• Do not install or operate this unit in a location where there is direct

sunlight, excessive heat, dust or vibration.

• Do not store or operate this unit near chemicals, or where there are

chemical fumes.

• Do not use the PL-FD200 in locations where corrosive gasses are

present

• To prevent damage to file data, be sure to shut down the PL unit's OS

before turning OFF the main power.

Warning - Safety Precautions

The PL-FD200 (FDD Unit) is an internally mounted 3.5 inch floppy disc
drive unit, designed for use with Pro-face’s Panel Computer, hereafter
referred to as the “PL.”

Corresponding PL unit: PL-X900,PL-X920 Series Units
All product names used in this document are the trademarks of their respective
manufacturers.
Pro-face: Digital Electronics Corporation

!!!!!

PL-FD200

Installation Guide

Summary of Contents for PL-FD200

Page 1: ...se may cause either a breakdown or an electrical shock Do not install or operate this unit in a location where there is direct sunlight excessive heat dust or vibration Do not store or operate this unit near chemicals or where there are chemical fumes Do not use the PL FD200 in locations where corrosive gasses are present To prevent damage to file data be sure to shut down the PL unit s OS before ...

Page 2: ...mmediately that the following items are included Installation Guide Pro face has taken the utmost care to insure the quality of this product when it was shipped However should for any reason problems or dam age have occurred during shipping please contact your local Pro face representative immediately for service ...

Page 3: ...Mean Time Between Failures 30 000 hours Ambient Operating Temperature 5 0 C to 50 0 C Ambient Storage Temperature 10 0 C to 60 0 C Ambient Humidity 20 to 80 RH no condensation Shock Resistance During shipping 980 7m s 2 Vibration Resistance During operation 9 8m s 2 10Hz to 25Hz The above specifications are for the PL FD210 unit only Pro face does not guarantee the preservation of any data stored ...

Page 4: ...nels located on the PL s side face by unscrew ing that panel s two 2 attach ment screws Then remove the blank panel This slot is reserved for the PL FD200 unit Do not insert this unit into any other slot 2 Insert the FDD unit into its installation slot along the inside guide rail until the FDD unit s connector contacts the rear connector receptacle and is inserted securely in place 3 Reattach the ...

Page 5: ...ts a separate menu area where settings can be entered 4 Use the cursor to select STANDARD CMOS SETUP and the fol lowing screen will appear STANDARD CMOS SETUP BIOS FEATURES SETUP CHIPSET FEATURES SETUP POWER MENAGEMENT SETUP PNP PCI CONFIGURATION LOAD BIOS DEFAULTS LOAD SETUP DEFAULTS SYSTEM MONITOR UTILITY INTEGRATED PERIPHERALS SUPERVISOR PASSWORD USER PASSWORD IDE HDD AUTO DETECTION SAVE EXIT S...

Page 6: ... hh mm ss 14 50 3 CYLS HEADS PRECOMP LANDZONE SECT0RS MODE Drive C Auto 0b 0 0 0 0 0 AUTO Drive D Auto 0b 0 0 0 0 0 AUTO Drive A 1 44M 3 5 in Video EGA VGA VGA Graphics Mode Normal Halt On All But Keyboard ESC Quit Select Item PU PD Modify F1 Help Shift F2 Change Color Base Memory 640K Extended Memory 31744K Other Memory 384K Total Memory 32768K Note Please be aware that Digital Electronics Corpor...