background image

Page 

2

 of 

3

 

 

Introduction 

The

 PNL-CIS4-DA

PNL-CIS4-M-DA and PNL-CIS4-M-L-DA

 are vandal resistant analog call station 

that incorporate the following options: 

 

Model 

Speaker 

Call Button  

Microphone 

LED Call Button 

PNL-CIS4-DA 

 

 

PNL-CIS4-M-DA 

 

PNL-CIS4-M-L-DA 

 

 

Specifications 

 

12 Gauge stainless steel Call Panel 

 

Integrated 8 Ohm Speaker 

– waterproof cone 

 

Integrated security screen to protect the speaker 

 

Integrated Microphone - water resistant (-M-DA and -M-L-DA) 

 

Integrated security screens to protect the microphone 

 

Integrated vandal resistant Call button (-DA, -M-DA) 

 

Integrated vandal resistant Call button with LED (-M-L-DA) 
 

 

Installation

  

 
Mounting 

The PNL-CIS4-x can be flush mounted into a standard 2-gang electrical box or surface mounted in 
an optional surface mount box.  For outdoor installations, mount under an eave or use a hooded 
surface mount box (PNL-BB7). 

 
Wiring Requirements when connecting to the IP7-FX 

– IP Audio Module 

For best results and to minimize interference, connect the Microphone to the IP7-FX with 18-20 AWG 
2 conductor SHIELDED wire. Connect the Shield to the J2-4 (GND) on the IP7-FX.  Do not connect 
the shield to the call station.

  

 
Use18 - 20 AWG for Speaker and the Call Button and LED.

 

 

If connecting the PNL-CIS4-x to the IP7-FX, the Microphone wire must not be in the same 
jacket as the Speaker wire.  

 

 

 

 