4.0. ACCESS CODE 

In order to execute the desired function of the Digit-KD, it is necessary to enter an access code 
and press a function button.   
-    The code may be made from of a minimum of 1 digit to a maximum of 4 digits (from 0  to  9). 
-  There  is  no  limit  in  the  choice  of  a  code:  the  digits  can  all  the  same,  or  they  can  be  all            
 

different.  Example: 2 - 305 - 119  8888 - 4567 etc.  

-  The control panel can learn and memorize a maximum of 8 different codes.  
-  For each code you may use an unlimited number of remote keypads. 

Enter  in  programming  mode  and  advance  to  self-
learning of keys.  
The  LED  “TEST”  quickly  flashes,  while  the  LED  
LOW BAT.” is lit fixed. On the display appears:

 

PROG  KEY   
ch.  n. 1 : no 

PROG  KEY   
ch.  n. 1 : no 

 

 

Digit a code (for example 1, 2, 3).  
3  asterisks  will  appear  on  the    
display.  

 

*** 

 

PROG  KEY  
ch.  n. 2 : no 

 

 

MAINT 
OK 

 

PROG  KEY   
ch.  n. 1 : si (yes) 

 

Press the button      to memorize the code.  
A  beep  is  emitted  from  the  control  panel  
confirming that the code has been learned. 
The  display  shows  the  message  on  the 
right. 

 

Failure  of  confirmation  on  the  display  that  the  code  has  been  learned,          
indicates that this code is already memorized in another position.  
Therefore, repeat operations described in points 2) and 3).  

 

4.1.  SELF-LEARNING OF ACCESS CODE 

To cancel the codes memorized, press the 
button “B” on the control panel.  
The  keypad  displays  the  message  shown 
on the right.  

 

To  enter  a  new code  in  position  n. 1  not  occupied, repeat the  operations 1), 
2), 3) and 4). 

 

To  move  to  the  next  position,  press  the 
button  “A” on the control panel and repeat 
operations 1), 2),  3) and 4) and so forth up 
to the eighth position.     

 

After having memorized the code or codes, 
exit programming  mode (see control  panel 
instructions).  On  the  display  the  message 
shown on the right will appear. 

 

Summary of Contents for VISION series

Page 1: ...intenance status 6 6 0 Disarming 6 7 0 Total arming DAY mode 7 8 0 Partial arming NIGHT mode 8 9 0 Arming Test Control DAY mode 9 10 0 Arming Test Control NIGHT mode 10 11 0 By passing zones 11 12 0 T...

Page 2: ...visualized Other characteristics Back light illumination of all buttons and display for approximately 30 seconds after a button is pressed In the case that more than one button is pressed the 30 secon...

Page 3: ...ing zone configuration immediate delayed With the control panel armed in Day or Night mode or disarmed if a tamper alarm is triggered the LED flashes slowly until the control panel is re armed FIRE Fi...

Page 4: ...t on the display indicate the zones in alarm or alarm memory In the example on the right zones 3 and 4 have been triggered and an alarm has taken place Buttons Are used to digit the access code Button...

Page 5: ...s will appear on the display PROG KEY ch n 2 no MAINT OK PROG KEY ch n 1 si yes Press the button to memorize the code A beep is emitted from the control panel confirming that the code has been learned...

Page 6: ...on the right MAINT OK 6 0 DISARMING With the control panel in Maintenance armed or Test Control status to disarm the control panel proceed as follows Digit one of any of the memorized codes example 1...

Page 7: ...ancellation that takes place after approximately 40 seconds ON OK ON OK zone by p If a few zones are by passed during the exit time on the display will appear the message zone by p instead of delay Pr...

Page 8: ...K ON OK Press the button to confirm The control panel emits one beep On the display the message on the right appears The writing ON and the LED UNIT ON will flash quickly After a few seconds the writi...

Page 9: ...y Keep in mind that only the alarm with the highest priority level is visualized entirely on the display and remains in memory until the control panel is re armed To verify if there have been other al...

Page 10: ...e Night group during the exit time on the display the message zone by p instead of delay will appear To verify the zones by passed or associated to the Night group proceed as indicated on the points 3...

Page 11: ...forth BY PASS zone 2 no To pass to the next zone press the button A message regarding the status of the second zone will appear on the display To by pass the zone press the button BY PASS zone 2 si y...

Page 12: ...e instructions of the control panel installed 12 0 TAMPER KEYPAD Even if the control panel is armed with the mechanical key the tamper of the remote keypad is always in function ATTENTION 13 0 TECHNIC...

Reviews: